© Agrowtek Inc. | www.agrowtek.com | Technology to Help You Grow™
59
Weather Positions
Ventilation and Shade control settings both feature weather override positions which can be set when the
system weather alarms are activated for rain, wind speed or low temperature.
To set weather position limits, turn on the Weather Positions switch and move the sliders to the desired posi-
tions.
TIP
To disable a specific weather override position, set the position to 100%.
This will prevent the override from reducing the position even if the alarm is active.
2
3
4
1
1. Weather Positions
Set this option to limit the position based on system weather alarms.
2. Rain Position Sets the maximum position allowed during a rain alarm.
3. Wind Position Sets the maximum position allowed during a high wind alarm.
4. Temperature Position
Sets the maximum position allowed during a low temperature alarm.