Private Sub OpenIo()
m_ResourceManager = New ResourceManagerClass()
m_IoObject = New FormattedIO488Class()
' Open the default VISA COM IO object.
Try
m_IoObject.IO = _
DirectCast(m_ResourceManager.Open(m_strVisaAddress, _
AccessMode.NO_LOCK, 0, ""), IMessage)
Catch e As Exception
Console.WriteLine("An error occurred: {0}", e.Message)
End Try
End Sub
Public Sub SetTimeoutSeconds(ByVal nSeconds As Integer)
m_IoObject.IO.Timeout = nSeconds * 1000
End Sub
Public Sub Close()
Try
m_IoObject.IO.Close()
Catch
End Try
Try
Marshal.ReleaseComObject(m_IoObject)
Catch
End Try
Try
Marshal.ReleaseComObject(m_ResourceManager)
Catch
End Try
End Sub
End Class
End Namespace
VISA COM Example in Python
You can use the Python programming language with the "comtypes"
package to control Agilent oscilloscopes.
The Python language and "comtypes" package can be downloaded from the
web at
"http://www.python.org/"
and
"http://starship.python.net/crew/theller/comtypes/"
, respectively.
To run this example with Python and "comtypes":
1
Cut- and- paste the code that follows into a file named "example.py".
2
Edit the program to use the VISA address of your oscilloscope.
3
If "python.exe" can be found via your PATH environment variable, open
a Command Prompt window; then, change to the folder that contains
the "example.py" file, and enter:
Содержание InfiniiVision 2000 X-Series
Страница 1: ...s1 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide...
Страница 24: ...24 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide...
Страница 38: ...38 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 1 What s New...
Страница 48: ...48 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 2 Setting Up...
Страница 62: ...62 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 3 Getting Started...
Страница 120: ...120 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 4 Commands Quick Reference...
Страница 206: ...206 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 8 BUS n Commands...
Страница 242: ...242 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 11 DEMO Commands...
Страница 250: ...250 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 12 DIGital d Commands...
Страница 270: ...270 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 14 DVM Commands...
Страница 276: ...276 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 15 EXTernal Trigger Commands...
Страница 312: ...312 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 17 HARDcopy Commands...
Страница 332: ...332 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 19 MARKer Commands...
Страница 416: ...416 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 22 POD Commands...
Страница 424: ...424 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 23 RECall Commands...
Страница 446: ...446 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 24 SAVE Commands...
Страница 588: ...588 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 28 TIMebase Commands...
Страница 692: ...692 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 31 WGEN Commands...
Страница 758: ...758 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 34 Error Messages...
Страница 788: ...788 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 36 Synchronizing Acquisitions...
Страница 918: ...918 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 38 Programming Examples...