32
Agilent InfiniiVision 2000 X-Series Oscilloscopes Programmer's Guide
1
What's New
What's New in Version 1.20
New features in version 1.20 of the InfiniiVision 2000 X- Series oscilloscope
software are:
•
X cursor units that let you measure time (seconds), frequency (Hertz),
phase (degrees), and ratio (percent), and Y cursor units that let you
measure the channel units (base) or ratio (percent).
•
Option for specifying FFT vertical units as V RMS as well as decibels.
•
Option for saving the maximum number of waveform data points.
More detailed descriptions of the new and changed commands appear
below.
New Commands
Command
Description
:FUNCtion[FFT]:VTYPe (see
page 283
)
Specifies FFT vertical units as DECibel or
VRMS.
:MARKer:XUNIts (see
page 325
)
Specifies the units for X cursors.
:MARKer:XUNIts:USE (see
page 326
)
Sets the current X1 and X2 cursor locations as
0 and 360 degrees if XUNIts is DEGRees or as 0
and 100 percent if XUNIts is PERCent.
:MARKer:YUNIts (see
page 330
)
Specifies the units for Y cursors.
:MARKer:YUNIts:USE (see
page 331
)
Sets the current Y1 and Y2 cursor locations as
0 and 100 percent if YUNIts is PERCent.
:SAVE:WAVeform:LENGth:MAX (see
page 442
)
Enable or disables saving the maximum
number of waveform data points.
:TRIGger:FORCe (see
page 592
)
Now documented, this command is equivalent
to the front panel [Force Trigger] key which
causes an acquisition to be captured even
though the trigger condition has not been met.
Содержание InfiniiVision 2000 X-Series
Страница 1: ...s1 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide...
Страница 24: ...24 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide...
Страница 38: ...38 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 1 What s New...
Страница 48: ...48 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 2 Setting Up...
Страница 62: ...62 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 3 Getting Started...
Страница 120: ...120 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 4 Commands Quick Reference...
Страница 206: ...206 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 8 BUS n Commands...
Страница 242: ...242 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 11 DEMO Commands...
Страница 250: ...250 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 12 DIGital d Commands...
Страница 270: ...270 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 14 DVM Commands...
Страница 276: ...276 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 15 EXTernal Trigger Commands...
Страница 312: ...312 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 17 HARDcopy Commands...
Страница 332: ...332 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 19 MARKer Commands...
Страница 416: ...416 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 22 POD Commands...
Страница 424: ...424 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 23 RECall Commands...
Страница 446: ...446 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 24 SAVE Commands...
Страница 588: ...588 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 28 TIMebase Commands...
Страница 692: ...692 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 31 WGEN Commands...
Страница 758: ...758 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 34 Error Messages...
Страница 788: ...788 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 36 Synchronizing Acquisitions...
Страница 918: ...918 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 38 Programming Examples...