s
1
183
Agilent InfiniiVision 2000 X-Series Oscilloscopes
Programmer's Guide
7
:ACQuire Commands
Set the parameters for acquiring and storing data. See
"Introduction to
:ACQuire Commands"
on page 183.
Introduction to
:ACQuire
Commands
The ACQuire subsystem controls the way in which waveforms are
acquired. These acquisition types are available: normal, averaging, peak
detect, and high resolution.
Normal
Table 57 :ACQuire Commands Summary
Command
Query
Options and Query Returns
:ACQuire:COMPlete
<complete> (see
page 185
)
:ACQuire:COMPlete?
(see
page 185
)
<complete> ::= 100; an integer in
NR1 format
:ACQuire:COUNt
<count> (see
page 186
)
:ACQuire:COUNt? (see
page 186
)
<count> ::= an integer from 2 to
65536 in NR1 format
:ACQuire:MODE <mode>
(see
page 187
)
:ACQuire:MODE? (see
page 187
)
<mode> ::= {RTIMe | SEGMented}
n/a
:ACQuire:POINts? (see
page 188
)
<# points> ::= an integer in NR1
format
:ACQuire:SEGMented:AN
ALyze (see
page 189
)
n/a
n/a (with Option SGM)
:ACQuire:SEGMented:CO
UNt <count> (see
page 190
)
:ACQuire:SEGMented:CO
UNt? (see
page 190
)
<count> ::= an integer from 2 to
25 in NR1 format (with Option
SGM)
:ACQuire:SEGMented:IN
Dex <index> (see
page 191
)
:ACQuire:SEGMented:IN
Dex? (see
page 191
)
<index> ::= an integer from 1 to
25 in NR1 format (with Option
SGM)
n/a
:ACQuire:SRATe? (see
page 194
)
<sample_rate> ::= sample rate
(samples/s) in NR3 format
:ACQuire:TYPE <type>
(see
page 195
)
:ACQuire:TYPE? (see
page 195
)
<type> ::= {NORMal | AVERage |
HRESolution | PEAK}
Содержание InfiniiVision 2000 X-Series
Страница 1: ...s1 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide...
Страница 24: ...24 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide...
Страница 38: ...38 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 1 What s New...
Страница 48: ...48 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 2 Setting Up...
Страница 62: ...62 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 3 Getting Started...
Страница 120: ...120 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 4 Commands Quick Reference...
Страница 206: ...206 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 8 BUS n Commands...
Страница 242: ...242 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 11 DEMO Commands...
Страница 250: ...250 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 12 DIGital d Commands...
Страница 270: ...270 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 14 DVM Commands...
Страница 276: ...276 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 15 EXTernal Trigger Commands...
Страница 312: ...312 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 17 HARDcopy Commands...
Страница 332: ...332 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 19 MARKer Commands...
Страница 416: ...416 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 22 POD Commands...
Страница 424: ...424 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 23 RECall Commands...
Страница 446: ...446 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 24 SAVE Commands...
Страница 588: ...588 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 28 TIMebase Commands...
Страница 692: ...692 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 31 WGEN Commands...
Страница 758: ...758 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 34 Error Messages...
Страница 788: ...788 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 36 Synchronizing Acquisitions...
Страница 918: ...918 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 38 Programming Examples...