What's New
1
Agilent InfiniiVision 2000 X-Series Oscilloscopes Programmer's Guide
37
Discontinued
Commands
Command
Description
:ACQuire:RSIGnal
The 2000 X-Series oscilloscope does not have a 10 MHz REF
BNC connector.
:CALibrate:SWITch?
Replaced by :CALibrate:PROTected? (see
page 212
). The
oscilloscope has a protection button instead of a switch.
:DISPlay:SOURce
PMEMory (pixel memory) locations are not present.
:EXTernal:IMPedance
External TRIG IN connector is now fixed at 1 MOhm.
:EXTernal:PROBe:ID
Not supported on external TRIG IN connector.
:EXTernal:PROBe:STYPe
Not supported on external TRIG IN connector.
:EXTernal:PROTection
Not supported on external TRIG IN connector.
:HARDcopy:DEVice,
:HARDcopy:FORMat
Use the :SAVE:IMAGe:FORMat, :SAVE:WAVeform:FORMat, and
:HARDcopy:APRinter commands instead.
:MERGe
Waveform traces have been replaced by reference waveforms.
:RECall:IMAGe[:STARt]
Waveform traces have been replaced by reference waveforms.
:SYSTem:PRECision
The 2000 X-Series oscilloscopes' measurement record, and
maximum record size, is 62,500 points, and there is no need for a
special precision mode.
:TIMebase:REFClock
The 2000 X-Series oscilloscope does not have a 10 MHz REF
BNC connector.
Содержание InfiniiVision 2000 X-Series
Страница 1: ...s1 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide...
Страница 24: ...24 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide...
Страница 38: ...38 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 1 What s New...
Страница 48: ...48 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 2 Setting Up...
Страница 62: ...62 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 3 Getting Started...
Страница 120: ...120 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 4 Commands Quick Reference...
Страница 206: ...206 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 8 BUS n Commands...
Страница 242: ...242 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 11 DEMO Commands...
Страница 250: ...250 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 12 DIGital d Commands...
Страница 270: ...270 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 14 DVM Commands...
Страница 276: ...276 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 15 EXTernal Trigger Commands...
Страница 312: ...312 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 17 HARDcopy Commands...
Страница 332: ...332 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 19 MARKer Commands...
Страница 416: ...416 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 22 POD Commands...
Страница 424: ...424 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 23 RECall Commands...
Страница 446: ...446 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 24 SAVE Commands...
Страница 588: ...588 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 28 TIMebase Commands...
Страница 692: ...692 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 31 WGEN Commands...
Страница 758: ...758 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 34 Error Messages...
Страница 788: ...788 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 36 Synchronizing Acquisitions...
Страница 918: ...918 Agilent InfiniiVision 2000 X Series Oscilloscopes Programmer s Guide 38 Programming Examples...