![Agilent Technologies E4428C Скачать руководство пользователя страница 236](http://html.mh-extra.com/html/agilent-technologies/e4428c/e4428c_user-manual_2867497236.webp)
212
Chapter 6
Analog Modulation
Configuring the LF Output
Configuring the LF Output
The signal generator has a low frequency (LF) output. The LF output’s source can be switched between an
internal modulation source or an internal function generator.
Using internal modulation (
Internal Monitor
) as the LF output source, the LF output provides a replica of the
signal from the internal source that is being used to modulate the RF output. The specific modulation
parameters for this signal are configured through the AM, FM, or FM menus.
Using function generator as the LF output source, the function generator section of the internal modulation
source drives the LF output directly. Frequency and waveform are configured from the LF output menu, not
through the AM, FM, or FM menus. You can select the waveform shape from the following choices:
Sine
sine wave with adjustable amplitude and frequency
Dual-Sine
dual-sine waves with individually adjustable frequencies and a percent-of-
peak-amplitude setting for the second tone (available from function generator only)
Swept-Sine
a swept-sine wave with adjustable start and stop frequencies, sweep time, and sweep
trigger settings (available from function generator only)
Triangle
triangle wave with adjustable amplitude and frequency
Ramp
ramp with adjustable amplitude and frequency
Square
square wave with adjustable amplitude and frequency
Noise
noise with adjustable amplitude generated as a peak-to-peak value (RMS value is
approximately 80% of the displayed value)
DC
direct current with adjustable amplitude
NOTE
The
LF Out Off On
softkey controls the operating state of the LF output. However when the
LF output source selection is
Internal Monitor
, you have three ways of controlling the output.
You can use the modulation source (AM, FM, or FM) on/off key, the LF output on/off key,
or the
Mod On/Off
softkey.
The
RF On/Off
hardkey does not apply to the LF OUTPUT connector.
Содержание E4428C
Страница 22: ...Contents xxii ...
Страница 107: ...Chapter 3 83 Basic Operation Using Security Functions Figure 3 6 ESG Screen with Secure Display Activated ...
Страница 182: ...158 Chapter 4 Basic Digital Operation Using Waveform Clipping Figure 4 22 Rectangular Clipping ...
Страница 183: ...Chapter 4 159 Basic Digital Operation Using Waveform Clipping Figure 4 23 Reduction of Peak to Average Power ...
Страница 224: ...200 Chapter 4 Basic Digital Operation Creating and Using Bit Files ...
Страница 228: ...204 Chapter 5 AWGN Waveform Generator Configuring the AWGN Generator ...
Страница 229: ...205 6 Analog Modulation ...
Страница 276: ...252 Chapter 7 Digital Signal Interface Module Operating the N5102A Module in Input Mode ...
Страница 286: ...262 Chapter 8 Bluetooth Signals Turning On a Bluetooth Signal ...
Страница 287: ...263 9 BERT This feature is available only in E4438C ESG Vector Signal Generators with Option 001 601or 002 602 ...
Страница 330: ...306 Chapter 9 BERT Verifying BERT Operation ...
Страница 366: ...342 Chapter 10 CDMA Digital Modulation IS 95A Modulation ...
Страница 394: ...370 Chapter 12 Multitone Waveform Generator Applying Changes to an Active Multitone Signal ...
Страница 454: ...430 Chapter 15 W CDMA Digital Modulation for Component Test W CDMA Concepts Figure 15 9 Uplink Channel Structure ...
Страница 468: ...444 Chapter 15 W CDMA Digital Modulation for Component Test W CDMA Frame Structures ...
Страница 667: ...643 18 Troubleshooting ...
Страница 700: ...Index 676 Index ...