140
Chapter 4
Basic Digital Operation
Using Waveform Markers
4. Name and store the waveform sequence
“Storing Waveform Segments to Non-Volatile Memory” on
The following figure shows a sequence built reusing the same factory-supplied waveform segment; a
factory-supplied segment has a marker point on the first sample for all four markers. In this example,
Marker 1 is enabled for the first segment, Marker 2 is enable for the second segment, and markers 3 and 4
are enabled for the third segment.
For each segment, only the markers enabled for that segment produce a rear-panel auxiliary output signal. In
this example, the Marker 1 auxiliary signal appears only for the first segment, because it is disabled for the
remaining segments. The Marker 2 auxiliary signal appears only for the second segment, and the marker 3
and 4 auxiliary signals appear only for the third segment.
In an Existing Waveform Sequence
If you have not already done so, create and store a waveform sequence that contains at least three segments
(
). Ensure that the segment or segments are available in volatile memory (
1. Press
Mode
>
Dual ARB
>
Waveform Sequences
, and highlight the desired waveform sequence.
2. Press
Edit Selected Waveform Sequence
, and highlight the first waveform segment.
3. Press
Enable/Disable Markers
>
Toggle Marker 1
,
Toggle Marker 2
,
Toggle Marker 3
, and
Toggle Marker 4
.
Toggling a marker that has no marker points (
) has no effect on the auxiliary outputs.
An entry in the
Mkr
column indicates that the marker is enabled for that segment; no entry in the column
means that all markers are disabled for that segment
4. Highlight the next waveform segment and toggle the desired markers (in this example, markers 1 and 4).
5. Repeat
as desired (for this example, select the third segment and toggle marker 3).
Sequence Marker Column
This entry shows that
markers 3 and 4 are enabled
for this segment.
Содержание E4428C
Страница 22: ...Contents xxii ...
Страница 107: ...Chapter 3 83 Basic Operation Using Security Functions Figure 3 6 ESG Screen with Secure Display Activated ...
Страница 182: ...158 Chapter 4 Basic Digital Operation Using Waveform Clipping Figure 4 22 Rectangular Clipping ...
Страница 183: ...Chapter 4 159 Basic Digital Operation Using Waveform Clipping Figure 4 23 Reduction of Peak to Average Power ...
Страница 224: ...200 Chapter 4 Basic Digital Operation Creating and Using Bit Files ...
Страница 228: ...204 Chapter 5 AWGN Waveform Generator Configuring the AWGN Generator ...
Страница 229: ...205 6 Analog Modulation ...
Страница 276: ...252 Chapter 7 Digital Signal Interface Module Operating the N5102A Module in Input Mode ...
Страница 286: ...262 Chapter 8 Bluetooth Signals Turning On a Bluetooth Signal ...
Страница 287: ...263 9 BERT This feature is available only in E4438C ESG Vector Signal Generators with Option 001 601or 002 602 ...
Страница 330: ...306 Chapter 9 BERT Verifying BERT Operation ...
Страница 366: ...342 Chapter 10 CDMA Digital Modulation IS 95A Modulation ...
Страница 394: ...370 Chapter 12 Multitone Waveform Generator Applying Changes to an Active Multitone Signal ...
Страница 454: ...430 Chapter 15 W CDMA Digital Modulation for Component Test W CDMA Concepts Figure 15 9 Uplink Channel Structure ...
Страница 468: ...444 Chapter 15 W CDMA Digital Modulation for Component Test W CDMA Frame Structures ...
Страница 667: ...643 18 Troubleshooting ...
Страница 700: ...Index 676 Index ...