![Aeris CompuMask Скачать руководство пользователя страница 132](http://html.mh-extra.com/html/aeris/compumask/compumask_operating-manual_2861741132.webp)
132
If it is necessary to clean the Battery Compartment, flush it
and all components with a solution of 50% white vinegar
and 50% fresh water. Rinse with fresh water, and allow to
dry overnight, or blow dry with a hair dryer set at no heat.
Mask Battery Installation
Lightly lubricate a new Battery Cover O-ring with silicone
grease and place it on the beveled outer edge of the Battery
Compartment (Fig. 116). Ensure that it is evenly seated.
The O-ring must be a genuine AERIS part. Use of any other
O-ring may result in an improper seal and leakage.
Place a new 3 volt, CR2, Lithium Battery (Duracell
®
model DL-
CR2 or equivalent) negative end first into the Battery Com-
partment with the negative end toward the Spring. Ensure
that the Battery is properly oriented.
Carefully place one side of the Battery Cover into position so
that it is seated on top of the Cover O-ring (Fig. 117) and
while holding it in place, press the other side down into
place.
While holding the Cover firmly in place, secure it with the 2
Screws by alternately turning each of them clockwise 1 turn
at a time.
The outer surface of the Battery Cover should be flush with
the outer surface of the Housing (Mask Frame).
Fig. 117 - BATTERY COVER
INSTALLATION
Fig. 116 - BATTERY
O-RING AND BATTERY
INSTALLED