AEQ
CAPITOL
Ultra-compact digital audio mixer
61
IMPORTANT NOTE:
In order to access to any of these submenus, it’s neccesary to have a
configuration loaded in the application (in case there’s no configuration, the message “
Empty
configuration. Please read configuration before use
” is displayed). Therefore, you have to
either connect to AEQ CAPITOL console and read its configuration or load a configuration by
means of “Import” option (see section 4.1.1 of this manual; you can find the
“DemoConfiguration.CSC” file in C:\Program files \CapitolSetup\Demos).
4.2.1.
“
Board Configuration
”
submenu.
“Board Configuration” submenu is accessed, from the drop-down menu “Hardware
Configuration”, by clicking on the icon:
“Board Configuration” submenu enables you to check the faders and inputs/outputs
configuration and to define the MADI module and GPIOs configuration.
From left to right and from top to bottom the available options are:
•
“
Console Configuration
”
:
informative maintenance field: there are 8 faders (2 logical
CACH modules with 4 faders each) in AEQ CAPITOL control surface.
•
“
Module Configuration
”
:
informative maintenance field: shows information about the
input and output logical modules at AEQ CAPITOL back panel.
•
“
Internal Module Configuration
”
:
allows you to configure the general purpose inputs
and outputs GPIO (both the physical contact relays and the opto-coupled). It also allows
you to configure the operation of the optional multi-channel AES10 MADI
communications module (available by means of user license: see section 4.1.1 of this
manual) as well as the remote sync extraction (through the first AES input or the MADI
link).