Section 4 User Interface Guide
61200624L1-1B
© 2004 ADTRAN, Inc.
53
S
YSTEM
C
ONFIG
> M
ANAGEMENT
> T
ELNET
A
CCESS
> A
CCESS
Sets
A
CCESS
to
O
N
or
O
FF
to allow or block telnet access to the unit. The factory default value for this
parameter is
O
N
.
S
YSTEM
C
ONFIG
> M
ANAGEMENT
> T
ELNET
A
CCESS
> A
UTHEN
M
ETHOD
Set up the Telnet authentication method from this menu. The choices are
L
OCAL
P
ASSWORD
,
R
ADIUS
,
L
OCAL
/R
ADIUS
, and
R
ADIUS
/L
OCAL
.
L
OCAL
/R
ADIUS
indicates that the unit will try Local Password
Authentication first, and if that fails, it will try Radius Authentication.
R
ADIUS
/L
OCAL
indicates that the unit
will try Radius authentication first, and if that fails, it will try Local Password authentication. The default is
L
OCAL
P
ASSWORD
.
S
YSTEM
C
ONFIG
> M
ANAGEMENT
> T
ELNET
P
ORT
Defines the TCP port number used when establishing a Telnet session. Normal Telnet port is
23
. Enter a
customized port number if desired. Make certain the Telnet program you use is configured for the same
port number (if using a customized port number).
S
YSTEM
C
ONFIG
> M
ANAGEMENT
> T
ELNET
A
CCESS
> U
SER
L
IST
Add Telnet users and control the Telnet access conditions through this menu.
#
Display the index number of the Telnet users. Up to four users can be configured for access to the
unit. Each user can be assigned a security level and idle time.
N
AME
The name is a text string of the user name for this session. The factory default is
U
NASSIGNED
in the
N
AME
field.You must enter a username in this field (up to 15 characters) because the Telnet entry is
not activated until it is assigned a valid username. Editing the
U
NASSIGNED
default to be blank is
allowed for a single Telnet entry; duplicate usernames are not allowed. During an active Telnet
session the
N
AME
is displayed in the Telnet Information field located at the bottom of the menu
screen.
P
ASSWORD
When the authenticating method is
L
OCAL
P
ASSWORD
, or
L
OCAL
/R
ADIUS
, this text string is used for
the password. You can enter up to 30 characters in this field. The factory default is no entry in this
field.
I
DLE
T
IME
(
MINS
)
This sets the amount of time in minutes you can be idle before you are automatically logged off. The
factory default is
10
MINUTES
. The range is
1
TO
255
MINUTES
.
L
EVEL
This is the security level granted to the user. Table 3 on page 54 gives a brief description of each
level. The factory default is
F
ULL
.
Содержание 606
Страница 14: ...Table of Contents Total Access 600 Series System Manual 14 2004 ADTRAN Inc 61200624L1 1B ...
Страница 186: ...Section 5 Detail Level Procedures Total Access 600 Series System Manual 184 2004 ADTRAN Inc 61200624L1 1B ...
Страница 196: ...Section 5 DLP 4 Total Access 600 Series System Manual 194 2004 ADTRAN Inc 61200624L1 1B ...
Страница 204: ...Section 5 DLP 6 Total Access 600 Series System Manual 202 2004 ADTRAN Inc 61200624L1 1B ...
Страница 208: ...Section 5 DLP 7 Total Access 600 Series System Manual 206 2004 ADTRAN Inc 61200624L1 1B ...
Страница 222: ...Section 5 DLP 13 Total Access 600 Series System Manual 220 2004 ADTRAN Inc 61200624L1 1B ...
Страница 232: ...Section 5 DLP 16 Total Access 850 System Manual 230 2004 ADTRAN Inc 64203376L1 1A ...
Страница 240: ...Section 5 DLP 18 Total Access 600 Series System Manual 238 2004 ADTRAN Inc 61200624L1 1B ...
Страница 244: ...Section 5 DLP 19 Total Access 600 Series System Manual 242 2004 ADTRAN Inc 61200624L1 1B ...
Страница 254: ...Section 6 ADTRAN Utilities Total Access 600 Series System Manual 252 2004 ADTRAN Inc 61200624L1 1B ...