Total Access 600 Series System Manual
Section 5 DLP-18
61200624L1-1B
© 2004 ADTRAN, Inc.
237
5. Once the L2 protocol detection is complete, the service provider can telnet into the unit using the IP
address assigned by the router/DHCP server.
6. Load the desired configuration file. The config file may be one of the following two formats:
•
A .cfg file which is loaded via TFTP. See DLP-9,
Saving the Current Configuration Using TFTP
.
•
A script obtained via the terminal mode. See DLP-13 (
Saving the Router's Configuration
section
only).
7. Set the failsafe timer by selecting
S
YSTEM
U
TILITY
> T
ERMINAL
M
ODE
and typing
fstimer start x
, (where
x is in seconds) at the > prompt. Select a value for x which will allow enough time for the service
provider to reconfigure the network to match the unit's new configuration and which will allow an extra
3 to 5 minutes for the unit to sync up with the network.
8. Type
Save
at the > prompt. This applies all configuration changes and the current connection is lost.
9. At this point, the service provider reconfigures the network to match the unit's new configuration.
10. After the network configuration is complete, the service provider attempts to connect to the unit. If the
connection is successful, deactivate the failsafe timer by selecting
S
YSTEM
U
TILITY
> T
ERMINAL
M
ODE
and typing
fstimer stop
at the > prompt.
11. If the connection is not successful, wait until the timer expires and the unit will factory default back to
the
A
UTO
-C
ONFIG
mode. Repeat steps 4-10 of this DLP.
The service provider's access network Layer 1 must be provisioned to map a single 64 K
DS0 from the provider's network to DS0 24 on the customer's T1 circuit with matching
circuit parameters (ESF, B8ZS).
Set the failsafe timer prior to doing the save. Typing
save
will apply the configuration
changes, and the unit will not be accessible until the network is reconfigured.
Содержание 606
Страница 14: ...Table of Contents Total Access 600 Series System Manual 14 2004 ADTRAN Inc 61200624L1 1B ...
Страница 186: ...Section 5 Detail Level Procedures Total Access 600 Series System Manual 184 2004 ADTRAN Inc 61200624L1 1B ...
Страница 196: ...Section 5 DLP 4 Total Access 600 Series System Manual 194 2004 ADTRAN Inc 61200624L1 1B ...
Страница 204: ...Section 5 DLP 6 Total Access 600 Series System Manual 202 2004 ADTRAN Inc 61200624L1 1B ...
Страница 208: ...Section 5 DLP 7 Total Access 600 Series System Manual 206 2004 ADTRAN Inc 61200624L1 1B ...
Страница 222: ...Section 5 DLP 13 Total Access 600 Series System Manual 220 2004 ADTRAN Inc 61200624L1 1B ...
Страница 232: ...Section 5 DLP 16 Total Access 850 System Manual 230 2004 ADTRAN Inc 64203376L1 1A ...
Страница 240: ...Section 5 DLP 18 Total Access 600 Series System Manual 238 2004 ADTRAN Inc 61200624L1 1B ...
Страница 244: ...Section 5 DLP 19 Total Access 600 Series System Manual 242 2004 ADTRAN Inc 61200624L1 1B ...
Страница 254: ...Section 6 ADTRAN Utilities Total Access 600 Series System Manual 252 2004 ADTRAN Inc 61200624L1 1B ...