9. Factory default the Total Access 612/616/624 by one of the following methods:
•
Select
S
YSTEM
U
TILITY
> T
ERMINAL
M
ODE
. At the > prompt, type
factory_reset
. You will then see
“Restore Factory Defaults and Reset Unit? (press
Y
).” Press the
Y
key to confirm default. The unit
then resets.
•
If connected to the
CRAFT
port (must be 9600 baud), power reset the unit and then restore power
to the unit while holding down the
F
key. You will then be prompted to confirm the factory default.
10. In the ATM code, the upgrade was successful if the
S
YSTEM
I
NFO
> F
IRMWARE
R
EVISION
field does not
display Error.
11. Reconfigure the unit for the specific application.
Purchase of a T1 TDM 612/616/624 Unit with the EC/ADPCM Card Installed for Later Upgrade to ATM
For customers who plan to operate a TDM application initially, but eventually upgrade to an ATM
application, a Total Access 612/616/624 unit may be purchased with the EC/ADPCM card installed
(P/N 4200612L2#TDM, 4200616L2#TDM, 4200642L2#TDM).
1. When the circuit is converted to ATM, the customer may obtain the latest VoATM firmware from the
ADTRAN website (http://www.ADTRAN.com). Select
S
UPPORT
> P
OST
-S
ALES
T
ECHNICAL
S
UPPORT
>
F
IRMWARE
U
PDATES
> 612/616/624 ATM
or contact Post-Sales Technical Support at 888-4ADTRAN.
2. Upgrade the Total Access 612/616/624 with the latest VoATM firmware (see
Updating the Firmware
using TFTP
and DLP-8,
Updating the Firmware using XMODEM
for details on upgrading the
firmware).
3. Factory default the Total Access 612/616/624 by one of the following methods:
•
Select
S
YSTEM
U
TILITY
> T
ERMINAL
M
ODE
. At the > prompt, type
fac
. You will then see “Restore
Factory Defaults and Reset Unit? (press
Y
).” Press the
Y
key to confirm default. The unit then resets.
•
If connected to the
CRAFT
port, power reset the unit and then restore power to the unit while
holding down the
F
key. You will then be prompted to confirm the factory default.
4. In the ATM code, the upgrade was successful if the following two things occur:
•
The
S
YSTEM
I
NFO
> F
IRMWARE
R
EVISION
field does not display Error.
Содержание 606
Страница 14: ...Table of Contents Total Access 600 Series System Manual 14 2004 ADTRAN Inc 61200624L1 1B ...
Страница 186: ...Section 5 Detail Level Procedures Total Access 600 Series System Manual 184 2004 ADTRAN Inc 61200624L1 1B ...
Страница 196: ...Section 5 DLP 4 Total Access 600 Series System Manual 194 2004 ADTRAN Inc 61200624L1 1B ...
Страница 204: ...Section 5 DLP 6 Total Access 600 Series System Manual 202 2004 ADTRAN Inc 61200624L1 1B ...
Страница 208: ...Section 5 DLP 7 Total Access 600 Series System Manual 206 2004 ADTRAN Inc 61200624L1 1B ...
Страница 222: ...Section 5 DLP 13 Total Access 600 Series System Manual 220 2004 ADTRAN Inc 61200624L1 1B ...
Страница 232: ...Section 5 DLP 16 Total Access 850 System Manual 230 2004 ADTRAN Inc 64203376L1 1A ...
Страница 240: ...Section 5 DLP 18 Total Access 600 Series System Manual 238 2004 ADTRAN Inc 61200624L1 1B ...
Страница 244: ...Section 5 DLP 19 Total Access 600 Series System Manual 242 2004 ADTRAN Inc 61200624L1 1B ...
Страница 254: ...Section 6 ADTRAN Utilities Total Access 600 Series System Manual 252 2004 ADTRAN Inc 61200624L1 1B ...