Section 4 User Interface Guide
Total Access 600 Series System Manual
166
© 2004 ADTRAN, Inc.
61200624L1-1B
Appendix D. Configuring the Unit for DSX-1 Applications
The Total Access 600 Series systems are available with an integrated DSX-1 interface for both voice and
data applications. Regardless of the application (either voice or data), the Total Access 6XX has the ability
to map DS0s from the network T1 to DS0s on the DSX-1 interface (cross-connect) without affecting the
data present on the DS0s. This feature allows the Total Access 6XX to support voice with dedicated
signaling channels (ISDN), voice with in-channel signaling information (Robbed Bit Signaling (RBS) to a
PBX, key system, etc.), as well as clear channel data to an external T1 router.
Initial Setup
It is best to configure Total Access 6XX TDM applications by following the order of the top-level menus.
For example, first configure the system parameters using the
S
YSTEM
I
NFO
and
S
YSTEM
C
ONFIG
menus.
Next, configure the Layer 1 parameters using the
I
NTERFACES
menu. Once the Layer 1 information is
configured, proceed to the Layer 2 setup using the
L2 P
ROTOCOL
menus. Follow the Layer 2 setup with the
data “routing” menus (either
B
RIDGE
or
R
OUTER
). Establish packet forwarding and blocking using the
S
ECURITY
menus. Lastly, configure the physical mappings using the
DS0 M
APS
menus.
The following example provides details for configuring the Total Access 6XX to pass analog voice over
the DSX-1 interface (using RBS), digital voice (fractional PRI with D-Channel), and data bandwidth. The
Total Access 6XX provides a single DSX-1 interface, so it is unlikely that your application will require all
three features on the DSX-1 interface simultaneously; therefore ignore any steps that do not pertain to your
application.
Perform the following steps in order to configure the applications (
I
NTERFACES
through
DS0 M
APS
).
S
YSTEM
I
NFO
and
S
YSTEM
C
ONFIG
parameters should be set according to your system need. Refer to
System
Info
on page 49 and
System Config
on page 51 for more details.
1. Setting up the Interfaces
For more details on the configuration parameters discussed in this section, refer to the following pages:
Network T1 menus beginning on
page 71
DSX-1 menus beginning on
page 78
T1 Interface Setup Instructions
Step
Action
1
From the main menu, select
I
NTERFACES
.
2
Highlight the
C
ONFIG
menu for the
T1
interface and press
<E
NTER
>
.
3
Right arrow to select
F
ORMAT
and choose
ESF
or
SF
.
This format must match the format used by the other units in the network.
4
Set the
L
INE
C
ODE
to
B8ZS
or
AMI
.
Содержание 606
Страница 14: ...Table of Contents Total Access 600 Series System Manual 14 2004 ADTRAN Inc 61200624L1 1B ...
Страница 186: ...Section 5 Detail Level Procedures Total Access 600 Series System Manual 184 2004 ADTRAN Inc 61200624L1 1B ...
Страница 196: ...Section 5 DLP 4 Total Access 600 Series System Manual 194 2004 ADTRAN Inc 61200624L1 1B ...
Страница 204: ...Section 5 DLP 6 Total Access 600 Series System Manual 202 2004 ADTRAN Inc 61200624L1 1B ...
Страница 208: ...Section 5 DLP 7 Total Access 600 Series System Manual 206 2004 ADTRAN Inc 61200624L1 1B ...
Страница 222: ...Section 5 DLP 13 Total Access 600 Series System Manual 220 2004 ADTRAN Inc 61200624L1 1B ...
Страница 232: ...Section 5 DLP 16 Total Access 850 System Manual 230 2004 ADTRAN Inc 64203376L1 1A ...
Страница 240: ...Section 5 DLP 18 Total Access 600 Series System Manual 238 2004 ADTRAN Inc 61200624L1 1B ...
Страница 244: ...Section 5 DLP 19 Total Access 600 Series System Manual 242 2004 ADTRAN Inc 61200624L1 1B ...
Страница 254: ...Section 6 ADTRAN Utilities Total Access 600 Series System Manual 252 2004 ADTRAN Inc 61200624L1 1B ...