Section 4 User Interface Guide
Total Access 600 Series System Manual
112
© 2004 ADTRAN, Inc.
61200624L1-1B
L2 P
ROTOCOL
(ATM–NET–C
U
MTN) > C
ONFIG
> N
UM
Displays the index number in the DLCI config table. The number range is
0-9
.
L2 P
ROTOCOL
(ATM–NET–C
U
MTN) > C
ONFIG
> A
CTIVE
When this parameter is set to
Y
ES
(def), the mapping is used to determine the protocols used. If set to
N
O
,
the unit will ignore the virtual circuit with this DLCI.
L2 P
ROTOCOL
(ATM–NET–C
U
MTN) > C
ONFIG
> I
NTERFACE
Shows the user the physical and logical port associated with each DLCI. This is a read-only field.
L2 P
ROTOCOL
(ATM–NET–C
U
MTN) > C
ONFIG
> DLCI
The DLCI (Data Link Connection Identifier) number identifies the virtual circuit being configured. The
DLCI range is
16-1023
. The default is
16-25
corresponding to the index numbers
0-9
respectfully.
L2 P
ROTOCOL
(ATM–NET–C
U
MTN) > C
ONFIG
> C
ONNECTION
Select the physical and logical method of data transfer over the virtual path. There are two valid connection
entries:
R
OUTER
and
V
OICE
. Select
R
OUTER
to connect traffic from this PVC to the Total Access 6XX
integral IP router. Select
V
OICE
to connect traffic from this PVC to a voice connection (normally an FXS
interface).
L2 P
ROTOCOL
(ATM–NET–C
U
MTN) > C
ONFIG
> S
ETUP
This submenu only appears for
V
OICE
connections. Configure the
C
ALL
C
ONTROL
for voice gateway using
this menu.
L2 P
ROTOCOL
(ATM–NET–C
U
MTN) > C
ONFIG
> S
ETUP
> C
ALL
C
ONTROL
The
C
ALL
C
ONTROL
setting is used to configure the correct Voice Gateway protocol for voice signaling
control between the Total Access 6XX and the configured Gateway. The Call Control setting must be
configured correctly before the voice circuits will work correctly. The Total Access 6XX supports
J
ETSTREAM
,
C
OPPERCOM
,
T
OLLBRIDGE
and
LES-CAS
(def).
L2 P
ROTOCOL
(ATM–NET–C
U
MTN) > S
TATUS
View the status of the Copper Mountain DLCI connections.
L2 P
ROTOCOL
(ATM–NET–C
U
MTN) > S
TATUS
> N
UM
Displays the index number for the Status menu entries.
L2 P
ROTOCOL
(ATM–NET–C
U
MTN) > S
TATUS
> S
UB
-I
NTERFACE
This is a read-only field which displays the physical and logical port of the interface using the following
nomenclature: [A.B], where A represents the physical port (network interface is 0, Ethernet is 1) and B
represents the logical port for the Layer 2 protocol (i.e. PVC for Frame Relay, PPP link, etc.) Each
configured logical port is assigned a number corresponding to the order in which they are listed in the L2
Protocol configuration fields.
Содержание 606
Страница 14: ...Table of Contents Total Access 600 Series System Manual 14 2004 ADTRAN Inc 61200624L1 1B ...
Страница 186: ...Section 5 Detail Level Procedures Total Access 600 Series System Manual 184 2004 ADTRAN Inc 61200624L1 1B ...
Страница 196: ...Section 5 DLP 4 Total Access 600 Series System Manual 194 2004 ADTRAN Inc 61200624L1 1B ...
Страница 204: ...Section 5 DLP 6 Total Access 600 Series System Manual 202 2004 ADTRAN Inc 61200624L1 1B ...
Страница 208: ...Section 5 DLP 7 Total Access 600 Series System Manual 206 2004 ADTRAN Inc 61200624L1 1B ...
Страница 222: ...Section 5 DLP 13 Total Access 600 Series System Manual 220 2004 ADTRAN Inc 61200624L1 1B ...
Страница 232: ...Section 5 DLP 16 Total Access 850 System Manual 230 2004 ADTRAN Inc 64203376L1 1A ...
Страница 240: ...Section 5 DLP 18 Total Access 600 Series System Manual 238 2004 ADTRAN Inc 61200624L1 1B ...
Страница 244: ...Section 5 DLP 19 Total Access 600 Series System Manual 242 2004 ADTRAN Inc 61200624L1 1B ...
Страница 254: ...Section 6 ADTRAN Utilities Total Access 600 Series System Manual 252 2004 ADTRAN Inc 61200624L1 1B ...