Total Access 600 Series System Manual
Section 4 User Interface Guide
61200624L1-1B
© 2004 ADTRAN, Inc.
105
L2 P
ROTOCOL
(ATM–NET–ATM) > C
ONFIG
> PVC C
ONFIG
> S
ETUP
(V35)
Use these menus to configure the V35 parameters for this logical connection from the T1 interface to the
V.35 port. These menus are only applicable when the
C
ONNECTION
parameter is set to
V35
.
M
AX
C
ONFIG
This value is the number of unanswered configuration-requests that should be
transmitted before resetting PPP negotiations. the possible values are
5
,
10
,
15
,
and
20
(def).
M
AX
T
IMER
(
SEC
)
This value is the number of seconds to wait between unanswered
configuration-requests. The possible values are
1
SEC
,
2
SECS
,
3
SECS
(
DEF
)
,
5
SECS
, and
10
SECS
.
M
AX
F
AILURE
Due to the nature of PPP, configuration option may not be agreed upon between
two PPP peers. This value is the number of configuration-naks that should occur
before an option is configuration-rejected. The possible values are
5
(
DEF
)
,
10
,
15
, and
20
.
F
ORCE
P
EER
IP A
DDRESS
This option forces the PPP to negotiate the IP address entered instead of
allowing another address to be assigned by the remote end. The default is
N
O
.
K
EEPALIVE
P
ERIOD
This option allows the user to generate PPP keepalive packets that can be sent
every
1
minute,
2
minutes, or every
5
minutes. A value of
0 (O
FF
)
disables the
PPP keepalive packet generating feature. The default is
0 (O
FF
)
.
PPP E
NCAPSULATION
This option allows the user to set the encapsulation modes for PPP over ATM.
LLC has an encapsulation header in the AAL5 frame indicating it is
encapsulating PPP. VC-Mux does not have a header, and is therefor dedicated to
using PPP. The choices are
LLC
or
VC-M
UX
. The default is
VC-M
UX
.
S
END
I
DENTIFICATION
When enabled, this option enables the Total Access 600 Series to send the
system identification code in response to a configure acknowledgement from the
peer equipment. For most peer routers this option should be configured as
Y
ES
.
If set to
N
O
, the Total Access 600 Series will accommodate peer routers that do
not correctly respond to the identification code.
Содержание 606
Страница 14: ...Table of Contents Total Access 600 Series System Manual 14 2004 ADTRAN Inc 61200624L1 1B ...
Страница 186: ...Section 5 Detail Level Procedures Total Access 600 Series System Manual 184 2004 ADTRAN Inc 61200624L1 1B ...
Страница 196: ...Section 5 DLP 4 Total Access 600 Series System Manual 194 2004 ADTRAN Inc 61200624L1 1B ...
Страница 204: ...Section 5 DLP 6 Total Access 600 Series System Manual 202 2004 ADTRAN Inc 61200624L1 1B ...
Страница 208: ...Section 5 DLP 7 Total Access 600 Series System Manual 206 2004 ADTRAN Inc 61200624L1 1B ...
Страница 222: ...Section 5 DLP 13 Total Access 600 Series System Manual 220 2004 ADTRAN Inc 61200624L1 1B ...
Страница 232: ...Section 5 DLP 16 Total Access 850 System Manual 230 2004 ADTRAN Inc 64203376L1 1A ...
Страница 240: ...Section 5 DLP 18 Total Access 600 Series System Manual 238 2004 ADTRAN Inc 61200624L1 1B ...
Страница 244: ...Section 5 DLP 19 Total Access 600 Series System Manual 242 2004 ADTRAN Inc 61200624L1 1B ...
Страница 254: ...Section 6 ADTRAN Utilities Total Access 600 Series System Manual 252 2004 ADTRAN Inc 61200624L1 1B ...