Section 5 DLP-8
Total Access 600 Series System Manual
208
© 2004 ADTRAN, Inc.
61200624L1-1B
Updating Firmware via the Console Menus
1. Connect to the Total Access 6XX using
CRAFT
(RJ-48) interface. Selecting a higher baud rate
connection makes the file transfer process faster. Verify that the baud rate setting on the Total Access
6XX matches the VT100 emulation software COM port settings.
If you are not already connected to the
CRAFT
interface (either with a VT100 compatible terminal or
with a PC running VT100 emulation software), follow the procedure in
DLP-1, Connecting a VT100
Terminal or PC to the CRAFT Port
. Connecting to the
CRAFT
interface limits the upgrade procedure
to XMODEM only.
2. Log in to the unit.
3. Go to the
S
YSTEM
U
TILITY
menu and select the
U
PGRADE
F
IRMWARE
menu; press
<Enter>
.
4. Go to the
T
RANSFER
M
ETHOD
menu and select
XMODEM
.
5. Select
S
TART
T
RANSFER
to start the update process. Enter
Y
to confirm the upgrade.
6. From the terminal emulation software, begin the XMODEM upload by using the appropriate command
sequence. If necessary, refer to the terminal emulation software documentation for help.
Also, when specifying the filename, ensure that the file transferred is the one provided by ADTRAN,
otherwise, the update will not complete successfully. This may take several minutes.
Because XMODEM data is being transferred in-band through the menu interface, the VT100 menus of
the Total Access 6XX will be inoperable from the
CRAFT
interface. You can cancel the update at any
time within the terminal emulation software. (Please consult the documentation provided by the
terminal emulation software to determine how to do this.)
7. When the update process has successfully completed, the following messages will display:
Verifying downloaded FLASH image...
Erasing FLASH...
Programming FLASH...
FLASH programmed successfully.
The Total Access 6XX will restart immediately and the user may then log back into the system.
Alternately, if the unit is part of a management cluster connected to the local network, you may use a
PC connected to the network to Telnet into the unit. By utilizing the
ETHERNET
port, the
Total Access 6XX may be quickly upgraded using TFTP, provided there is a TFTP server on the local
network. The Total Access 6XX ships with ADTRAN Utilities software, which includes a TFTP
server. See
DLP-7, Updating the Firmware using TFTP
, for more details.
Perform the steps below in the order listed.
Total Access 6XX XMODEM transfers are compatible with both XMODEM and
1K XMODEM on the VT100 terminal system. Selecting 1K XMODEM on your terminal
session will make the configuration transfer faster.
Содержание 606
Страница 14: ...Table of Contents Total Access 600 Series System Manual 14 2004 ADTRAN Inc 61200624L1 1B ...
Страница 186: ...Section 5 Detail Level Procedures Total Access 600 Series System Manual 184 2004 ADTRAN Inc 61200624L1 1B ...
Страница 196: ...Section 5 DLP 4 Total Access 600 Series System Manual 194 2004 ADTRAN Inc 61200624L1 1B ...
Страница 204: ...Section 5 DLP 6 Total Access 600 Series System Manual 202 2004 ADTRAN Inc 61200624L1 1B ...
Страница 208: ...Section 5 DLP 7 Total Access 600 Series System Manual 206 2004 ADTRAN Inc 61200624L1 1B ...
Страница 222: ...Section 5 DLP 13 Total Access 600 Series System Manual 220 2004 ADTRAN Inc 61200624L1 1B ...
Страница 232: ...Section 5 DLP 16 Total Access 850 System Manual 230 2004 ADTRAN Inc 64203376L1 1A ...
Страница 240: ...Section 5 DLP 18 Total Access 600 Series System Manual 238 2004 ADTRAN Inc 61200624L1 1B ...
Страница 244: ...Section 5 DLP 19 Total Access 600 Series System Manual 242 2004 ADTRAN Inc 61200624L1 1B ...
Страница 254: ...Section 6 ADTRAN Utilities Total Access 600 Series System Manual 252 2004 ADTRAN Inc 61200624L1 1B ...