Total Access 600 Series System Manual
Section 5 DLP-13
61200624L1-1B
© 2004 ADTRAN, Inc.
219
5. Enable "capture" or "logging" in the terminal software, saving it to a file on your computer.
6. Press the
SPACE BAR
to continue. The unit prints its configuration to the terminal screen. (With
capture enabled, the terminal software will capture the configuration and write it to the designated file.)
7. When the configuration stops printing, end the capture. The unit configuration is now saved to the
designated file.
8. At the terminal prompt, type
EXIT
to enter the unit configuration menu.
Loading a configuration into the Total Access 6XX
The following steps explains the process for uploading the text file back into the Total Access 6XX. These
text files can be the entire configuration, or just partial commands that affect specific configuration
changes. The uploading steps are the same, regardless of the size of the file.
1. Establish a connection to the Total Access 6XX with the VT100 terminal software using the
CRAFT
port or Telnet via the
10/100BASET
Ethernet interface.
2. From the main menu, select
S
YSTEM
U
TILITY
, then
T
ERMINAL
M
ODE
; press
<Enter>
.
3. In the terminal software, initiate a SEND TEXT FILE or SEND CFG FILE using the saved configuration
file.
4. Once the file transfer is complete, type
SAVE
to save the configuration in the unit. Type
EXIT
to enter
the unit configuration menu.
Entering commands at the command prompt
Precede each instruction with a ">" when manually entering commands at the command prompt. After
entering commands, type
SAVE
at the command prompt. (This applies ALL commands to current
operation and saves all changes.) To save the changes to flash only (without affecting current operation),
return to the menu system and press <
CTRL+W
>.
The commands are based on string comparisons with the menu system (with spaces replaced with
underscores). For example, the config command appears at the command prompt exactly as it appears in
the Total Access 6XX terminal menus. To change a configuration, type in the desired option exactly as it
appears on the menu. For example, to change the T1 timing mode, the command line should read
>interfaces t1 config timing_mode network (sets timing to recover from the network)
or
>interfaces t1 config timing_mode internal (sets timing to internal Total Access 6XX oscillator)
or
>interfaces t1 config timing_mode dsx-1 (sets timing to recover from the DSX-1 interface).
Always use
<
CTRL
+
L
>
to exit the configuration menu before closing the Telnet or
terminal software.
Always use
<
CTRL
+
L
>
to exit the configuration menu before closing the Telnet or
terminal software.
Содержание 606
Страница 14: ...Table of Contents Total Access 600 Series System Manual 14 2004 ADTRAN Inc 61200624L1 1B ...
Страница 186: ...Section 5 Detail Level Procedures Total Access 600 Series System Manual 184 2004 ADTRAN Inc 61200624L1 1B ...
Страница 196: ...Section 5 DLP 4 Total Access 600 Series System Manual 194 2004 ADTRAN Inc 61200624L1 1B ...
Страница 204: ...Section 5 DLP 6 Total Access 600 Series System Manual 202 2004 ADTRAN Inc 61200624L1 1B ...
Страница 208: ...Section 5 DLP 7 Total Access 600 Series System Manual 206 2004 ADTRAN Inc 61200624L1 1B ...
Страница 222: ...Section 5 DLP 13 Total Access 600 Series System Manual 220 2004 ADTRAN Inc 61200624L1 1B ...
Страница 232: ...Section 5 DLP 16 Total Access 850 System Manual 230 2004 ADTRAN Inc 64203376L1 1A ...
Страница 240: ...Section 5 DLP 18 Total Access 600 Series System Manual 238 2004 ADTRAN Inc 61200624L1 1B ...
Страница 244: ...Section 5 DLP 19 Total Access 600 Series System Manual 242 2004 ADTRAN Inc 61200624L1 1B ...
Страница 254: ...Section 6 ADTRAN Utilities Total Access 600 Series System Manual 252 2004 ADTRAN Inc 61200624L1 1B ...