Section 5 DLP-16
Total Access 850 System Manual
228
© 2004 ADTRAN, Inc.
64203376L1-1A
1. Connect to the unit using either the
10/100BASET
or
CRAFT
interfaces.
If you are not already connected to the unit’s
CRAFT
interface (either with aVT100 compatible
terminal or with a PC running VT100 emulation software), follow the procedure in DLP-1,
Connecting
a VT100 Terminal or PC to the CRAFT Port
.
Alternately, if the unit is part of a management cluster connected to the local network, you may use a
PC connected to the network to Telnet into the unit. Use the procedures in DLP-3,
Setting IP
Parameters
, and DLP-5,
Connecting to the Unit Using Telnet
, to connect to the
10/100BASET
interface.
2. Log in to the unit (see DLP-2,
Logging in to the System
, for details).
3. Go to
S
YSTEM
U
TILITY
> T
ERMINAL
M
ODE
and press
<Enter>
. From this prompt you can:
a. Perform a reset with the command
reset
b. Perform a factory restore with the command
factory_reset
c. Configure the unit. The unit has the ability to download a text file which contains the configuration
of the entire unit. This configuration may then be altered in a text editor, and then uploaded to a
unit.
d. Debug and troubleshoot. This function would be carried out with the assistance of ADTRAN
Technical Support.
e. Start and stop the fail-safe time for the auto-config feature.
fs_timer start x
(
x
is in seconds) OR
fs_timer stop
f. Perform a firmware upgrade via TFTP.
upgrade_firmware
hostname filename
g. Use the
save
command to write the entire configuration flash.
h. Display the unit’s MAC address with the command
mac
.
i.
Perform a ping or extended ping. Syntax is:
ping hostname/address [repeat xx] [size xx] [timeout xx] [source xx] [no Nat]
Options:
repeat <repeat count>
Number of pings to send (default 5)
size (datagram size)
Range is 40-1500
timeout (seconds)
Timeout in seconds (range 1-10)
source (address or name)
Source address or interface name to use
noNat
Do not NAT the ping packet
Options may be entered in any order and may be truncated.
Valid interface names are eth0, fdl0, ppp0, fr0, fr1, etc.
Example usage:
ping 10.0.0.5 r 10 si 1500 so eth0 n
This will ping with a repeat count of 10. The datagram size is 1500 bytes, and the source address used
in the ping packet will be the ethernet IP address. The “noNat” option has been specified, so if NAT is
enabled, this packet will NOT be translated.
Perform the steps below in the order listed.
Содержание 606
Страница 14: ...Table of Contents Total Access 600 Series System Manual 14 2004 ADTRAN Inc 61200624L1 1B ...
Страница 186: ...Section 5 Detail Level Procedures Total Access 600 Series System Manual 184 2004 ADTRAN Inc 61200624L1 1B ...
Страница 196: ...Section 5 DLP 4 Total Access 600 Series System Manual 194 2004 ADTRAN Inc 61200624L1 1B ...
Страница 204: ...Section 5 DLP 6 Total Access 600 Series System Manual 202 2004 ADTRAN Inc 61200624L1 1B ...
Страница 208: ...Section 5 DLP 7 Total Access 600 Series System Manual 206 2004 ADTRAN Inc 61200624L1 1B ...
Страница 222: ...Section 5 DLP 13 Total Access 600 Series System Manual 220 2004 ADTRAN Inc 61200624L1 1B ...
Страница 232: ...Section 5 DLP 16 Total Access 850 System Manual 230 2004 ADTRAN Inc 64203376L1 1A ...
Страница 240: ...Section 5 DLP 18 Total Access 600 Series System Manual 238 2004 ADTRAN Inc 61200624L1 1B ...
Страница 244: ...Section 5 DLP 19 Total Access 600 Series System Manual 242 2004 ADTRAN Inc 61200624L1 1B ...
Страница 254: ...Section 6 ADTRAN Utilities Total Access 600 Series System Manual 252 2004 ADTRAN Inc 61200624L1 1B ...