Section 2 Engineering Guidelines
Total Access 600 Series System Manual
28
© 2004 ADTRAN, Inc.
61200624L1-1B
4.
REVIEWING THE REAR PANEL DESIGN
The Total Access 600R provides a
NTWK
connection (via an RJ-48 connector), a
CRAFT
interface (via an
RJ-49 connector), a
10/100BASET
interface (via an RJ-48 connector), and an
AC PWR
connection (via a
3-prong detachable power cord). In addition, systems can include the optional
DSX-1
interface (via an
RJ-48 connector). The Total Access 600R rear panel differs from the rest of the family in that it does not
have a
VOICE
connection (50-pin amphenol connector). Figure 4 illustrates a standard Total Access 600R
rear panel.
Figure 4. Total Access 600R Rear Panel
All other Total Access 600 Series systems contain the following rear panel interfaces regardless of the
model:
VOICE
connection (via a 50-pin female amphenol connector), a
NTWK
connection (via an RJ-48
connector), a
CRAFT
interface (via an RJ-48 connector), a
10/100BASET
interface (via an RJ-48
connector), a
V.35
connection (via a 34-pin Winchester-style connector), a
BATT
connection (via a 3-pin
modular plug), and an
AC PWR
connection (via a 3-prong detachable power cord). In addition, systems
can include either a
LIFE LINE
analog interface (via an RJ-48 connector) or an optional
DSX-1
interface
(via an RJ-48 connector). Figure 5 on page 29 illustrates a standard Total Access 604/608, and Figure 6
and Figure 7 on page 29 illustrate the Total Access 604/608 rear panels with the
LIFE LINE
analog and
DSX-1
interfaces, respectively. Figures 8 through 10 on page 29 illustrate the Total Access 612/616/624
rear panels.
BATT
Off
there is no power connected to the system.
Green (solid)
AC power is operational and battery is functional.
Red/Green (alternating)
AC power is operational, but the battery is not functional.
Amber (solid)
AC power has failed and the battery is functional.
Red/Amber (alternating)
AC power has failed and the battery is not functional.
PWR NET
Green (solid)
Layer 1 is up.
Green (blinking)
Layer 1 is down.
Table 5. Total Access 612/616/624 TDM Front Panel LEDs
(Continued)
For these LEDs... This color light...
Indicates that...
Содержание 606
Страница 14: ...Table of Contents Total Access 600 Series System Manual 14 2004 ADTRAN Inc 61200624L1 1B ...
Страница 186: ...Section 5 Detail Level Procedures Total Access 600 Series System Manual 184 2004 ADTRAN Inc 61200624L1 1B ...
Страница 196: ...Section 5 DLP 4 Total Access 600 Series System Manual 194 2004 ADTRAN Inc 61200624L1 1B ...
Страница 204: ...Section 5 DLP 6 Total Access 600 Series System Manual 202 2004 ADTRAN Inc 61200624L1 1B ...
Страница 208: ...Section 5 DLP 7 Total Access 600 Series System Manual 206 2004 ADTRAN Inc 61200624L1 1B ...
Страница 222: ...Section 5 DLP 13 Total Access 600 Series System Manual 220 2004 ADTRAN Inc 61200624L1 1B ...
Страница 232: ...Section 5 DLP 16 Total Access 850 System Manual 230 2004 ADTRAN Inc 64203376L1 1A ...
Страница 240: ...Section 5 DLP 18 Total Access 600 Series System Manual 238 2004 ADTRAN Inc 61200624L1 1B ...
Страница 244: ...Section 5 DLP 19 Total Access 600 Series System Manual 242 2004 ADTRAN Inc 61200624L1 1B ...
Страница 254: ...Section 6 ADTRAN Utilities Total Access 600 Series System Manual 252 2004 ADTRAN Inc 61200624L1 1B ...