112144 - 46
www.adclaundry.com
51
12. Steam damper system is not functioning properly (steam models only)...
a. Steam damper is sticking closed or is not adjusted properly.
b. Leak in pneumatic (air) system.
13. Failed electric element (electric models only).
14. Lint accumulation in location exhaust system.
V. Condensation on main door glass...
1. Too long, undersized, or improperly installed ductwork.
2. Exhaust back draft damper is stuck closed or partially closed.
3. Restriction in exhaust ductwork.
W. Dryer is making scraping noise at basket (tumbler) area...
1. Check for object(s) caught in the basket (tumbler) wrapper area.
2. Basket (tumbler) is out of proper alignment...
a. Check both the vertical alignment and lateral alignment.
b. Check gap between the front panel and the basket (tumbler)...setscrews may have come loose and basket
(tumbler) walked forwards or backwards.
3. Loose or broken basket (tumbler) tie rod.
4. Broken basket (tumbler) support.
X. Excessive noise and/or vibration...
1. Dryer is not leveled properly.
2. Impellor (fan) is out of balance or broken.
3. Loose basket (tumbler) tie rod.
4. Basket (tumbler) is out of adjustment or adjustment bolts (hardware) are loose.
5. Loose motor or motor mount assembly.
Y. Basket (tumbler) turns too fast (as opposed to other basket [tumbler])...
1. Foreign object(s) caught between basket (tumbler) belt and motor shaft.