8. The possible presence of residual quantities of aggressive or decomposed chemicals in the load may produce
damage to the machine and harmful fumes.
9. A program
should be
established for the inspection and cleaning of lint in the heating unit area, exhaust ductwork,
and inside the dryer. The frequency of inspection and cleaning can best be determined from experience at each
location.
WARNING:
The collection of lint in the burner area and exhaust ductwork can create a potential fire
hazard.
10. For personal safety, the dryer
must be
electrically grounded in accordance with local codes and/or the National
Electrical Code ANSI/NFPA NO. 70-LATEST EDITION or in Canada, the Canadian Electrical Codes Parts 1
& 2 CSA C22.1-1990 or LATEST EDITION.
NOTE:
Failure to do so will VOID THE WARRANTY.
11.
UNDER
NO
CIRCUMSTANCES
should the dryer door switch, lint door switch, or heat safety circuit ever be
disabled.
WARNING: PERSONAL INJURY OR FIRE COULD RESULT
.
12. This dryer is not to be used in the presence of dry cleaning solvents or fumes.
13. Remove articles from the dryer as soon as the drying cycle has been completed.
WARNING:
Articles left in the dryer after the drying and cooling cycles have been completed can
create a fire hazard.
14.
DO NOT
operate steam dryers with more than 125 PSI (8.62 bar) steam pressure. Excessive steam pressure
can damage steam coil and/or harm personnel.
15. Replace leaking flexible hoses or other steam fixtures immediately.
DO NOT
operate the dryer with leaking
flexible hoses. Personal injury may result.
16.
READ AND FOLLOW ALL CAUTION AND DIRECTION LABELS ATTACHED TO THE DRYER.
17. For safety, proper operation, and optimum performance, the dryer
must not be
operated with a load less than
sixty-six percent (66%) of its rated capacity. AD-320 (26.4 lbs [12 kg]) and AD-330 (39.7 lbs [18 kg]).
WARNING: YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLY AND
THE GAS SUPPLY OR THE STEAM SUPPLY BEFORE ANY COVERS OR
GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR
CLEANING, ADJUSTING, INSTALLATION, OR TESTING OF ANY
EQUIPMENT PER OSHA
(Occupational Safety and Health Administration)
STANDARD.
IMPORTANT: Dryer
must be
installed in a location/environment, which the ambient
temperature remains between 40º F (4.44º C) and 130º F (54.44º C).