112144 - 46
www.adclaundry.com
35
3) Start the dryer by pressing the desired setting for either the upper basket (tumbler) or lower basket
(tumbler) (i.e., “LO” selection for the upper basket [tumbler]). The light emitting diode (L.E.D.) display
will now read selection (setting) made and the amount of time vended (i.e., “LO 10”).
NOTE:
The dryer can be stopped at any time by opening the main door. To restart the dryer, shut the
main door and press the desired setting.
4) Open the main door to stop the dryer and change selection to “PERM PRESS” (medium) setting. Repeat
this procedure, but change the selection (setting) to “HI” (high). This will confirm that the setting key
circuits and door switch circuits are functioning properly.
NOTE:
Selection (setting) changes can be made at any time during the drying cycle by opening and
closing the main door and then making a new selection.
5) Repeat above procedure for the other basket (tumbler).
b. OPL (Non-Coin) Models Only
1) The L.E.D. display(s) will flash back and forth between “FILL” and “FrEE” meaning that the dryer is
available.
2) Start the dryer by pressing the desired setting for either the upper basket (tumbler) or lower dryer basket
(tumbler) (i.e., “LO” selection for the upper basket [tumbler]). The L.E.D. display will now read selection
(setting) made and the drying time portion of the L.E.D. display will read “00” and count upwards in
time.
NOTE:
The dryer can be stopped at any time by opening the main door. To restart the dryer, shut the
main door and press the desired setting.
3) Open the main door to stop the dryer and change selection to “PERM PRESS” (medium) setting. Repeat
this procedure, but change the selection (setting) to “HI” (high). This will confirm that the setting key
circuits and door switch circuits are functioning properly.
NOTE:
Selection (setting) changes can be made at any time during the drying cycle by opening and
closing the main door and then making a new selection.
4) Repeat above procedure for the other basket (tumbler).
3. Heat Circuit Operational Test
a. Gas Models
When a gas dryer is first started (during initial start-up), it has a tendency not to ignite on the first ignition
attempt. This is because the gas supply piping is filled with air, so it may take a few minutes for the air to be
purged from the lines.
The dryer is equipped with a Direct Spark Ignition (DSI) system, which has internal diagnostics. If ignition
is not established, the heat circuit DSI module will lockout until it is manually reset. To reset the DSI
system, open and close the main door and restart the dryer (press desired temperature selection).
Содержание AD-320
Страница 20: ...16 American Dryer Corp 112144 46 ...
Страница 21: ...112144 46 www adclaundry com 17 ...
Страница 22: ...18 American Dryer Corp 112144 46 ...
Страница 25: ...112144 46 www adclaundry com 21 ...
Страница 60: ...ADC Part No 112144 46 07 24 14 ...