G. GAS INFORMATION
It is your responsibility to have
ALL
plumbing connections made by a qualified professional to assure that the gas
plumbing installation is adequate and conforms to local and state regulations or codes. In the absence of such codes,
ALL
plumbing connections, materials, and workmanship
must conform
to the applicable requirements of the National
Fuel Gas Code ANSI Z223.1-LATEST EDITION, or in Canada, the Canadian Installation Codes CAN/CGA-B149.1-
M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION.
In Australia, the fuel gas code is AS 5601/AG 601, local authority, gas, electricity, and any other relevant statutory
regulations.
IMPORTANT:
Failure to comply with these codes or ordinances, and/or the requirements stipulated
in this manual, can result in personal injury and improper operation of the dryer.
The dryer and its individual shutoff valve
must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
The dryer
must be
isolated from the gas supply piping system by closing its individual manual shutoff valve during
any pressure testing of the gas supply system at test pressures equal to or less than 1/2 psig (3.5 kPa).
IMPORTANT:
Failure to isolate or disconnect the dryer from supply as noted can cause irreparable
damage to the gas valve, which will VOID THE WARRANTY.
WARNING: FIRE OR EXPLOSION COULD RESULT
.
1. Gas Supply
The gas dryer installation
must meet
the American National Standard...National Fuel Gas Code ANSI Z223.1-
LATEST EDITION, or in Canada, the Canadian Installation Codes CAN/CGA-B149.1 M91 (Natural Gas) or
CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION, as well as local codes and ordinances and
must be
done by a qualified professional.
NOTE:
Undersized gas piping will result in ignition problems, slow drying, increased use of energy,
and can create a safety hazard.
The dryer
must be
connected to the type of heat/gas indicated on the dryer data label located on the inside of
the middle access (control) door. If this information does not agree with the type of gas available, contact the
reseller who sold the dryer or contact the
ADC
factory.
IMPORTANT:
Any burner changes or conversions
must be
made by a qualified professional.
The input ratings shown on the dryer data label are for elevations up to 2,000 feet (609.6 meters) unless
elevation requirements of over 2,000 feet (609.6 meters) were specified at the time the dryer order was placed
with the factory. The adjustment or conversion of dryers in the field for elevations over 2,000 feet (609.6
meters) is made by changing each burner orifice. If this conversion is necessary, contact the reseller who sold
the dryer or contact the
ADC
factory.
IMPORTANT:
THIS GAS DRYER
IS NOT
PROVIDED WITH AN INTERNAL GAS SUPPLY
SHUTOFF AND AN EXTERNAL GAS SUPPLY SHUTOFF
MUST BE
PROVIDED.