1 Operation Points and Startup
1-9
1.8 Prober
Startup
“Startup” refers to the procedures from power-up to the completion of prober initialization.
When the POWER ON switch is pressed and lit, the
initialization screen (shown on left) is displayed.
The “Operation mode” can be set to [Operator],
[Engineer], [Manager] or [System], depending on the
nature of the prober operation and on the skill level of
the user. (By default, [Operator] is selected at
power-up.)
To change the operation mode, touch the <System
Mode Change> button. The second screen shown on
the left is displayed.
Touch the switch for [Engineer], [Manager] or [System],
and input the preset password (up to 8 alphanumeric
characters) to switch the operation mode. (The
password for each operation level is set to ‘12345678’
at shipment. Passwords are registered as part of the
[Prober Configuration Data]. Engineer level data can
contain the password for the Engineer level only;
Manager level data can contain a password each for
both the Engineer level and the Manager level.)
Input the password (the password is not shown on the
screen) and touch the <ENT> button. You will be
returned to the initialization screen. In the Engineering
mode, <Config. Data Change> and <Init. All Axes>
buttons become available. In the Manager and System
mode, <Mainte/Adjust> button further becomes
available.
Touch the <START> button on the initialization screen
to start the initialization of the prober.
If there is a wafer left in the loader unit, an error will
result. The wafer is transferred to the inspection tray,
and an ejection request is displayed. A wafer left on the
chuck also causes an error. The chuck is moved to the
front door, and a wafer ejection request is displayed.
Touch the ALARM OFF key to stop the buzzer, and
follow the instructions on the screen.