5 - Installation
I
ndependent channel configuration (default configuration)
This configuration uses the two
input channels (MPPT) independently.
This means that the jumper (supplied) between the positive poles of the
DC (MPPT1) connectors
28
and the DC (MPPT2) connectors
27
must
not be installed and that the mode which must be selected during the
guided setup for commissioning the system is “INDEPENDENT”.
C
onfiguration of parallel-connected channels
This configuration uses the two
input channels (MPPT) connected in
parallel.
This means that the jumper (supplied) between the positive poles of the
DC (MPPT1) connectors
28
and the DC (MPPT2) connectors
27
must
be installed and that the mode which must be selected during the guided
setup for commissioning the system is “PARALLEL”.