![ABB REACT-3.6-TL Скачать руководство пользователя страница 140](http://html.mh-extra.com/html/abb/react-3-6-tl/react-3-6-tl_product-manual_4163140.webp)
- 140 -
000569BG
7 - Operation
M
eter Menu
Select the
Meter
menu to access the following sub-menus:
Meter > Settings
Selecting
Settings
brings up the first screen relating to the password.
The default password is “0000”.
Enter the password using the keys on the display:
• DOWN scrolls down the numerical scale (from 9 to 0)
• UP scrolls up the numerical scale (from 0 to 9)
• ENTER confirms and moves to next digit
• ESC returns to the previous digit (from right to left)
• Press ESC several times to return to the previous menus
1. Meter Model
Allows you to set the type of meter connected to the REACT system:
• No meter
. No meter connected
• REACT-MTR-1PH
. Single-phase meter connected to system
• REACT-MTR-3PH
. Three-phase meter connected to system
2. Meter Address
Allows you to set the RS485 address assigned to the meter connected
to the REACT system
3. Meter com
• Baud Rate
. Allows you to set the Baud Rate (19200/57600/115200)
• Parity
. It allows you to set the Parity bit (None, Even, Odd).
Meter > Info
Select
Info
to access the following sub-menus:
1. Type
Displays the type of meter connected to the REACT system
2. Part No.
Displays the model code
3. Serial No.
Displays the serial number and week and year of manufacture of the
equipment
4. FW Rel.
Lets you view the revision of the
firmware installed on the equipment.
> Statistics
> Self consumpti.
> Self sufficien.
> Ener. from grid
> Ener. to grid
> Ener. to load
> PV en. to load
> PV ener.
> Settings
> Info
> Measures
> Set time
Password 0000
> Set cash
> Set RS485 com
> Country Select
> New password
> SD Update Info
> Energy Policy
Inverter
> Statistics
> Settings
> Vstart
> Input mode
> Input UV Delay
> Service
> Info
> Part No.
> Serial No.
> Firmware
> Remote ON/OFF
> MPPT Scan
> Power Limit.
> Reactive Power
> Autotest
> Alarms
> Backup
> Lifetime
> Partial
> Today
> Last 7 days
> Last 30 days
> Last 365 days
> User Period
Display
> Settings
> Backlight
> Contrast
> Buzzer
> Power Graph
> Language
Meter
> Settings
> Info
> Type
> Part No.
> Serial No.
> FW Rel.
> Measures
> Voltage
> Active Power
> Line current
> Load current
> Frequency
> Meter model
> Meter Address
> Meter com
Battery
> General
**
****
Load Manager
> info
> Relay Status
****
WIFI Logger
> Settings
> Info
> Part No.
> Serial No.
> View IP
> View Mode
> Restore AP
*
System
****
Password 0000
Password 0000
Password 0000
> Settings
> Info
> Nom. Cap
> Measures
> Ibat
> Vbat
> Pbat
> RE
> SOC
> SOH
> RT
> Battery Model
> Battery Packs
Password 0000
> Pack 1
> Settings
> Info
> Device Name
> Serial No.
> FW Rel.
> Nom. Capacity
> Init. Capacity
> Status
> Warning
> Alarms
> Measures
> Pack 1 enable
> Smoke Sensor
Password 0000
> Statistics
> Energy dischar.
> E-day
> E-7d
> E-30d
> E-365
> E-tot
> Ibat
> Vbat
> Pbat
> Tbat
> FCC
> RC
> RE
> TED
> SOC
> SOH
> TUT
> TDT
> RT
> CC
Скачано
с
сайта
интернет
магазина
https://axiomplus.com.ua/