![ABB REACT-3.6-TL Скачать руководство пользователя страница 139](http://html.mh-extra.com/html/abb/react-3-6-tl/react-3-6-tl_product-manual_4163139.webp)
- 139 -
000569BG
7 - Operation
D
isplay Menu
Select the
Display
menu to access the following sub-menus:
Display > Settings
Selecting
Settings
brings up the first screen relating to the password.
The default password is “0000”.
Enter the password using the keys on the display:
• DOWN scrolls down the numerical scale (from 9 to 0)
• UP scrolls up the numerical scale (from 0 to 9)
• ENTER confirms and moves to next digit
• ESC returns to the previous digit (from right to left)
• Press ESC several times to return to the previous menus
1. Backlight
This section of the menu allows you to set the display's backlighting cha-
racteristics:
•
Mode.
Allows you to set from:
- ON: Light always on
- OFF: Light always off
- AUTO: Automatic light control. The backlighting comes on whenever a
button is pressed and stays on for 30 sec, after which it gradually dims
out.
•
Intensity:
adjustment of display brightness (scale from 1 to 9)
2. Contrast
This section of the menu allows you to set the contrast of the display (on
a scale of 1 to 9).
3. Buzzer
Enabling/Disabling key sounds
4. Power Graph
This section of the menu allows you to set the type of graph that will be
displayed in the graph section of the display. In particular:
• Auto
. Displays the 5 graphs listed below cyclically, changing the graph
every 5 seconds.
• PW Vs Grid
. Display of energy fed into and taken from the grid.
• PW Vs Batt
. Display of energy fed into and taken from the battery.
• Battery SOC
. Display of state of charge of the battery.
• PW to Load
. Display of the energy used to fulfil the request from do
-
mestic loads.
• REACT Prod
. Display of total energy production of the system
5. Language
Allows you to set the required menu language
> Statistics
> Self consumpti.
> Self sufficien.
> Ener. from grid
> Ener. to grid
> Ener. to load
> PV en. to load
> PV ener.
> Settings
> Info
> Measures
> Set time
Password 0000
> Set cash
> Set RS485 com
> Country Select
> New password
> SD Update Info
> Energy Policy
Inverter
> Statistics
> Settings
> Vstart
> Input mode
> Input UV Delay
> Service
> Info
> Part No.
> Serial No.
> Firmware
> Remote ON/OFF
> MPPT Scan
> Power Limit.
> Reactive Power
> Autotest
> Alarms
> Backup
> Lifetime
> Partial
> Today
> Last 7 days
> Last 30 days
> Last 365 days
> User Period
Display
> Settings
> Backlight
> Contrast
> Buzzer
> Power Graph
> Language
Meter
> Settings
> Info
> Type
> Part No.
> Serial No.
> FW Rel.
> Measures
> Voltage
> Active Power
> Line current
> Load current
> Frequency
> Meter model
> Meter Address
> Meter com
Battery
> General
**
****
Load Manager
> info
> Relay Status
****
WIFI Logger
> Settings
> Info
> Part No.
> Serial No.
> View IP
> View Mode
> Restore AP
*
System
****
Password 0000
Password 0000
Password 0000
> Settings
> Info
> Nom. Cap
> Measures
> Ibat
> Vbat
> Pbat
> RE
> SOC
> SOH
> RT
> Battery Model
> Battery Packs
Password 0000
> Pack 1
> Settings
> Info
> Device Name
> Serial No.
> FW Rel.
> Nom. Capacity
> Init. Capacity
> Status
> Warning
> Alarms
> Measures
> Pack 1 enable
> Smoke Sensor
Password 0000
> Statistics
> Energy dischar.
> E-day
> E-7d
> E-30d
> E-365
> E-tot
> Ibat
> Vbat
> Pbat
> Tbat
> FCC
> RC
> RE
> TED
> SOC
> SOH
> TUT
> TDT
> RT
> CC
Скачано
с
сайта
интернет
магазина
https://axiomplus.com.ua/