- 120 -
000569BG
7 - Operation
D
escription of the menus
The ABB inverters are equipped with a graphical display
07
, consisting of
2 lines of 16 characters each, which can be used to:
• Display the operating status of the inverter and the statistical data
• Display service messages for the operator
• Display the alarm and fault messages
• Change the inverter settings.
G
eneral information
While the inverter is operating, the display shows various items of infor-
mation on the main parameters measured, the operating conditions and
the inverter's operating status.
The sequence of screens displayed is shown below, with a description of
the parameters monitored.
Alarm description
Warning/Error xxx
Inverter OK
Mon 22 Jan 15:55
E-day xxx.xkWh
$-day xx.xEUR
E-tot xxx.xkWh
E-par xxx.xkWh
Pout xxxxW
Lim XX% Pnom
Psetpoint xxx%
Regulation Type
COSp x.xxx
DOWN
UP
DOWN
UP
DOWN
UP
Backup: xxxxxxx
xxxxW XXXX
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
UP
Ppk xxxxW
Ppk-Day xxxxW
DOWN
UP
Vgrid xxxV
Igrid xx.xV
Fgrid xx.xxHz
DOWN
UP
Riso xx.xM©
Ileak x.xxxxA
Vbulk xxxV
Vbulk_m xxxV
DOWN
UP
DOWN
UP
DOWN
UP
Vin1 xxxV
Iin1 xx.xA
Vin2 xxxV
Iin2 xx.xA
Pin1 xxxxW
Pin2 xxxxW
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
UP
Vin xxxV
Iin xx.xA
Pin xxxxW
DOWN
UP
Inverter status: The code for any malfunction will be displayed.
Date and time as set on the inverter
Presence of
Errors/Warnings
No
Errors/Warnings
E-day: Daily energy produced
$-day : Today's savings/earnings
Value and graphical representation of the energy fed into or taken from the grid. Power fed into grid=bars and
arrow towards . Power taken from grid=bars and arrow towards the symbol -. Zero exchange with
the grid= central down arrow with words ZERO NET POWER.
E-tot: Energy produced since the inverter was commissioned
E-par: Partial energy produced since the last reset
Backup:
Backup mode set
Pout: Instantaneous output power
Lim XX%: Limitation applied to the nominal output power
Psetpoint: Intervention threshold for the output nominal power limit set
*
*
Regulation Type:
Mode for regulating the reactive power currently set
COSp: Phase difference set for feeding in reactive power
Ppk:
Maximum output power peak since the inverter was commissioned
Ppk-Day:
Maximum daily output power peak
Vgrid:
Measurement of output voltage
Igrid:
Measurement of output current
Fgrid:
Measurement of output frequency
Riso: Insulation resistance on DC input side (PV generator)
Ileak:
Leakage current on DC input side (PV generator)
Vbulk:
Internal voltage at the bulk capacitor terminals (booster circuit)
Vbulk_m:
Internal voltage at the bulk capacitor mid-point (booster circuit)
* Present only if the value or mode have been set
Vin 1: Input voltage channel 1
Vin: Input voltage
Iin 1: Input current channel 1
Iin: Input current
Vin 2: Input voltage channel 2
Iin 2: Input current channel 2
Pin1: Instantaneous input power channel 1
Pin: Instantaneous input power
Pin2: Instantaneous input power channel 2
Independent
inputs
Parallel
inputs