- 103 -
000567AG
6 - Instruments
Ref. Description
b10
Displays the total energy from the inverter installation
b11
Shows the energy produced throughout the day
b12
Indicates that the PV generator voltage is greater than the inverter Vstart
b13
Indicates the input channel (or the list) for which the data relating to the input parameters are shown in
the field
b22
b14
Indicates the DC/DC input circuit part (Booster)
b15
Indicates the DC to AC conversion circuit (inverter)
b16
Indicates the serial communication line between the REACT system and the METER. The icon in the
form of an X, if lit, indicates the lack of communication between the two devices
b17
Indicates the METER
b18
Indicates the output voltage phase (or the list) for which the data relating to the output parameters are
shown in the field
b25
b19
Indicates the status of the grid voltage:
Icon absent: no grid voltage
Flashing icon: grid voltage present but outside the parameters set by the grid standard
Icon present: Grid voltage present and within parameters set by the standard grid
b20
Cyclic display of the input parameters
b21
Cyclic display of storage parameters (batteries)
b22
Indicates the status of the battery charge
b23
When the ENTER key is pressed, cyclic display of the parameters can be:
blocked ( ) or cyclic ( )
b24
Cyclic display of the output parameters
b25
Cyclic display of the parameters relating to the domestic loads
b26
Representation of domestic loads
Depending on the operating conditions of the system, the graphics of the
display behave dynamically. Below are some examples.
Example 1:
- Photovoltaic production of 4.5kW. This production is distributed in:
- 3kW is supplied to the house to meet the power requirement of domestic
loads
- 1kW is used to charge the battery (the line between the icon representing
the inverter has the arrow pointed towards the battery. This means that
the battery is charged)
- 0.5kW of surplus power produced is fed into the grid (the line between
the symbol representing the meter and the supply point has the arrow
pointed towards the grid. This means that the power is being fed into the
grid)