5 - Installation
B
ack-up output connection (AC)
To connect the back-up output of the inverter, you need 3 connections:
ground, neutral and phase.
In any case, connection of the inverter to
ground is mandatory.
Any failure of the inverter when it is not connected to ground through the appropriate terminal
is not covered by the warranty.
Install the filter on the AC cable gland
49
(side inside the REACT-UNO). The
installation is carried out:
-
a
position the filter on the internal side of the cable gland
-
b
Screw the filter on the thread of the cable gland
a
b
Insert the grid cable into the inverter using the AC cable gland
49
called AC
-1 (M25 equipped with toroid) and make the connections to the AC output
terminal block
24
.
Use a properly sized tripolar cable and check the tightness of the AC cable
gland
49
at the end of the installation.