![ABB REACT-3.6-TL Скачать руководство пользователя страница 142](http://html.mh-extra.com/html/abb/react-3-6-tl/react-3-6-tl_product-manual_4163142.webp)
- 142 -
000569BG
7 - Operation
Battery Menu
Select the
Battery
menu to access the following sub-menus:
Battery > General > Settings
Selecting
Settings
brings up the first screen relating to the password.
The default password is “0000”.
Enter the password using the keys on the display:
• DOWN scrolls down the numerical scale (from 9 to 0)
• UP scrolls up the numerical scale (from 0 to 9)
• ENTER confirms and moves to next digit
• ESC returns to the previous digit (from right to left)
• Press ESC several times to return to the previous menus
1. Battery Model
Allows you to set the type of batteries connected to the REACT system:
• None
. No battery (REACT-BATT) connected
• REACT-BATT-AP1
. Panasonic battery pack connected to system.
2. Battery Packs
Allows you to set the number of batteries (REACT-BATT) connected to
the REACT system (from 1 to 3)
Battery > General > Info
Select
Info
to access the following sub-menus:
1. Nom. Cap
Displays the nominal capacity (in Ah) of the batteries connected to the
REACT system.
Battery > General > Measure
Select the
Measure
menu to access the following sub-menus:
1. Ibat
Battery current value
2. Vbat
Battery voltage value
3. Pbat
Battery power value
4. RE
Value of energy available in storage system
> Statistics
> Self consumpti.
> Self sufficien.
> Ener. from grid
> Ener. to grid
> Ener. to load
> PV en. to load
> PV ener.
> Settings
> Info
> Measures
> Set time
Password 0000
> Set cash
> Set RS485 com
> Country Select
> New password
> SD Update Info
> Energy Policy
Inverter
> Statistics
> Settings
> Vstart
> Input mode
> Input UV Delay
> Service
> Info
> Part No.
> Serial No.
> Firmware
> Remote ON/OFF
> MPPT Scan
> Power Limit.
> Reactive Power
> Autotest
> Alarms
> Backup
> Lifetime
> Partial
> Today
> Last 7 days
> Last 30 days
> Last 365 days
> User Period
Display
> Settings
> Backlight
> Contrast
> Buzzer
> Power Graph
> Language
Meter
> Settings
> Info
> Type
> Part No.
> Serial No.
> FW Rel.
> Measures
> Voltage
> Active Power
> Line current
> Load current
> Frequency
> Meter model
> Meter Address
> Meter com
Battery
> General
**
****
Load Manager
> info
> Relay Status
****
WIFI Logger
> Settings
> Info
> Part No.
> Serial No.
> View IP
> View Mode
> Restore AP
*
System
****
Password 0000
Password 0000
Password 0000
> Settings
> Info
> Nom. Cap
> Measures
> Ibat
> Vbat
> Pbat
> RE
> SOC
> SOH
> RT
> Battery Model
> Battery Packs
Password 0000
> Pack 1
> Settings
> Info
> Device Name
> Serial No.
> FW Rel.
> Nom. Capacity
> Init. Capacity
> Status
> Warning
> Alarms
> Measures
> Pack 1 enable
> Smoke Sensor
Password 0000
> Statistics
> Energy dischar.
> E-day
> E-7d
> E-30d
> E-365
> E-tot
> Ibat
> Vbat
> Pbat
> Tbat
> FCC
> RC
> RE
> TED
> SOC
> SOH
> TUT
> TDT
> RT
> CC