Note
Action
xx1300000534
In order not to damage the cable harness
later, it shall be moved over to the other
side of the arm house and be placed on the
right side (as seen from behind) of the back
lifting eye.
See figure!
5
How to remove the DressPack is described
in more detail in the product manual "IRB
6700 DressPack". For article number see
.
xx1400000195
If the robot is equipped with DressPack:
•
Open the two ball joint housings on
the lower arm and lift away the cable
harness from the ball joint housings.
6
If the robot is equipped with DressPack:
7
Lift the DressPack cable package at the
arm house up and put the cable bracket on
the cable guide where the velcro strap
normally is fitted. Secure the temporary
position with a velcro strap or similar, to
ensure it will not fall down or damage any-
thing.
Continues on next page
Product manual - IRB 6700
749
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
4 Repair
4.8.5 Replacing the axis-3 gearbox
Continued
Содержание IRB 6700 - 150/3.20
Страница 1: ...ROBOTICS Product manual IRB 6700 ...
Страница 2: ...Trace back information Workspace R18 2 version a18 Checked in 2018 11 20 Skribenta version 5 3 012 ...
Страница 46: ...This page is intentionally left blank ...
Страница 110: ...This page is intentionally left blank ...
Страница 786: ...This page is intentionally left blank ...
Страница 812: ...This page is intentionally left blank ...
Страница 836: ...This page is intentionally left blank ...
Страница 838: ...This page is intentionally left blank ...
Страница 845: ......