Concluding procedure
Note
Action
There are two versions of the heat protec-
tion plates.
Make sure that the cable harness is placed
in a way so it will not be damaged when
the wrist cover is fitted.
1
Choose figure depending on which plate
is installed on the robot.
xx1500001672
xx1300000596
Cable layout in the wrist with Type A mo-
tors.
A
B
xx1400000383
A Protection plugs (2 on wrist cover
and 2 on cover axis-5 gearbox)
B Washers (10 pcs) in gasket holes
Inspect the gasket. Replace if damaged.
Foundry Plus and Foundry Prime
:
•
Make sure that the gasket is undam-
aged on the cover. Replace if dam-
aged.
•
Put washers in the holes of the gas-
ket.
•
Use attachment screws made of
stainless steel to fit the wrist cover.
2
Continues on next page
Product manual - IRB 6700
363
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
4 Repair
4.5.2 Replacing the wrist