Parameters in the Long parameter mode
No.
Name/Value
Description
Default
4016
PI FEEDBACK SIGNAL
SOURCE SELECT
0
0
Analog Input 2(Terminal 4)
1
Analog Input 1(Terminal 6)
2
Motor Current
3
DC Bus voltage
4
Analog 1- Analog 2
5
Largest (Analog 1, Analog 2)
53
COMMUNICATION
PARAMETERS
5302
SERIAL
COMMUNICATIONS
CONFIGURATION
This parameter has three sub settings used to configure the Modbus RTU
Serial Communications. The Sub Parameters are:
Drive Address
:
Adr 0 to Adr 63
Baud Rate
:
For Modbus RTU 9.6kbps to 115.2kbps
For CAN Open 125, 250, 500, 1000kbps
Watchdog Timeout
:
0 (Disabled, 30, 100, 1000, 3000 milliseconds)
A “
t
” suffix selects trip on loss of communication. An “
r
” suffix means that
the drive will coast to stop (output immediately disabled) but will not trip.
Address 1
115.2 kbps
3000 msec
99
START-UP DATA
Digital Input Configuration and Motor Data Parameter
9902
DIGITAL INPUTS
FUNCTION SELECT
Defines the function of the digital inputs depending on the control mode
setting in Parameter
1103
PRIMARY COMMAND SOURCE MODE. See
Chapter 9 for detailed examples.
0
Range 0 to 14
See Chapter 9 Control Modes for 9902 parameter selection details
9905
MOTOR (BEMF)
VOLTAGE
This parameter should be set to the rated (nameplate) BEMF voltage of the
motor. See Chapter 2 for information on locating motor nameplate data.
Motor Rating
Dependent
110V/230V rated drives
0…250V
400V rated drives
0…500V
Voltage
Note
: The stress on the motor insulation is always dependent on the
drive supply voltage. This also applies to the case where the motor
voltage rating is lower than the rating of the drive and the supply of
the drive.
9906
MOTOR RATED
CURRENT
This parameter should be set to the rated (nameplate) current of the motor.
See Chapter 2 for information on locating motor nameplate data.
Motor Rating
Dependent
0.25*drive rated output
current…1.0*drive rated output
current
Current
9907
MOTOR RATED
FREQUENCY
This parameter should be set to the rated (nameplate) frequency of the
motor. See Chapter 2 for information on locating motor nameplate data.
60Hz
25…500Hz
Frequency
9908
MOTOR RATED SPEED
This parameter can optionally be set to the rated (nameplate) rpm of the
motor. When set to the default value of zero, all speed related parameters
are displayed in Hz, and the slip compensation for the motor is disabled.
Entering the value from the motor nameplate enables the slip compensation
function, and the DRIVE display will now show motor speed in estimated
rpm. All speed related parameters, such as Minimum and Maximum Speed,
Preset Speeds etc. will also be displayed in RPM.
0 RPM
0…4000 RPM
Содержание EC Titanium ECS100A1H1DF4
Страница 1: ... MN448_May 2020 May 2020 EC Titanium Manual User s guide ...
Страница 10: ...1 4 Introduction MN448 ...
Страница 20: ...3 4 Mechanical Information and Mounting MN448 ...
Страница 26: ...4 6 Electrical Installation and Planning MN448 ...
Страница 32: ...5 6 Control Pad Wiring and Keypad Interface MN448 ...
Страница 36: ...6 4 Keypad Programming and Basic Operation MN448 ...
Страница 44: ...8 4 Parameter Navigation and Groups MN448 ...
Страница 51: ...9 7 Control Modes MN448 ...
Страница 77: ...11 8 Standalone Motor and ABB Drive Setup MN448 ...
Страница 99: ...A 12 Modbus RTU Example Connection MN448 ...
Страница 102: ......