Version with type of protection II 3G for measurement of
non-flammable gases and vapors
Intended application
The AO2000 Series gas analyzers with analyzer modules Uras26, Magnos206,
Magnos27, Caldos25 and Caldos27 with type of protection II 3G have been
tested for explosion protection and are suitable for use in hazardous areas
in compliance with the technical data (see page 37) and the special condi-
tions for operation (see below). They are suitable for continuous measure-
ment of the concentration of individual components in non-flammable gases
or vapors.
Any other use is not as specified.
The specified use also includes taking note of this operating instruction.
Important safety note
According to EU Directive 2014/34/EU and the general requirements for
equipment installed in explosive atmospheres stated in IEC 60079-0, the
scope of the certification of our equipment is limited to atmospheric condi-
tions, unless specified otherwise in our certificates.
Atmospheric conditions
are defined as follows:
•
Temperature range
−
20 to +60 °C
•
Pressure range p
abs
= 80 to 110 kPa (0.8 to 1.1 bar)
•
Ambient air with normal oxygen content, typically 21 % v/v
If the
atmospheric conditions are not met
, the operator is obliged to ensure
the safe operation of our equipment outside the atmospheric conditions by
means of further measures (for example, assessment of the gas mixture)
and / or supplementary protection devices.
Description
The explosion-protected version with type of protection II 3G for the meas-
urement of non-flammable gases and vapors is a special version of the
AO2000 Series gas analyzers.
This version is different from other versions by the following designation on
the identification plate:
II 3G Ex nA nC IIC T4 Gc
Operating the gas analyzer under regular conditions cannot cause any ig-
nitable sparks, arcs or impermissible temperatures inside the device.
NOTE
For further information please refer to the Declaration of Conformity. The
Declaration of Conformity can be found on the DVD-ROM "Software tools
and technical documentation" which is delivered together with the gas ana-
lyzer.