Fault tracing 219
000A (Asynchronous motors only)
Deceleration did not finish
within reasonable time.
Contact your local ABB representative.
000B (Asynchronous motors only)
Speed dropped to zero during
ID run.
Contact your local ABB representative.
000C (Permanent magnet motors
only)
First acceleration did not finish
within reasonable time.
Contact your local ABB representative.
000D (Permanent magnet motors
only)
Second acceleration did not
finish within reasonable time.
Contact your local ABB representative.
000E…0010 Internal error.
Contact your local ABB representative.
0011 (Synchronous reluctance
motors only)
Pulse test error.
Contact your local ABB representative.
0012 Motor too large for advanced
standstill ID run.
Check that the motor and drive sizes are
compatible.
Contact your local ABB representative.
0013 (Asynchronous motors only)
Motor data error.
Check that the motor nominal value
settings in the drive are the same as in
the motor nameplate.
Contact your local ABB representative.
FF63
STO diagnostics
failure.
SW internal malfunction.
Reboot the control unit (using parameter
or by cycling
power.
FF81
FB A force trip
A fault trip command has been
received through fieldbus
adapter A.
Check the fault information provided by
the PLC.
FF8E
EFB force trip
A fault trip command has been
received through the
embedded fieldbus interface.
Check the fault information provided by
the PLC.
Code
(hex)
Fault / Aux. code
(
aux
code visible only on
assistant control panel
and drive composer
)
Cause
What to do
ACQ80 FW.book Page 219 Thursday, February 14, 2019 11:33 AM
Содержание ACQ80-04 Series
Страница 4: ...4 ACQ80 FW book Page 4 Thursday February 14 2019 11 33 AM ...
Страница 10: ...10 Table of contents ACQ80 FW book Page 10 Thursday February 14 2019 11 33 AM ...
Страница 16: ...16 Introduction to the manual ACQ80 FW book Page 16 Thursday February 14 2019 11 33 AM ...
Страница 26: ...26 Start up control with I O and ID run ACQ80 FW book Page 26 Thursday February 14 2019 11 33 AM ...
Страница 28: ...28 Using the control panel ACQ80 FW book Page 28 Thursday February 14 2019 11 33 AM ...
Страница 54: ...54 Program features ACQ80 FW book Page 54 Thursday February 14 2019 11 33 AM ...
Страница 196: ...196 Additional parameter data ACQ80 FW book Page 196 Thursday February 14 2019 11 33 AM ...
Страница 220: ...220 Fault tracing ACQ80 FW book Page 220 Thursday February 14 2019 11 33 AM ...
Страница 260: ...260 Fieldbus control through a fieldbus adapter ACQ80 FW book Page 260 Thursday February 14 2019 11 33 AM ...
Страница 264: ...264 Parameterization with drive composer ACQ80 FW book Page 264 Thursday February 14 2019 11 33 AM ...
Страница 268: ...268 Parameterization with automation builder drive manager ACQ80 FW book Page 268 Thursday February 14 2019 11 33 AM ...