Parameters 127
36
Peak value and amplitude logger settings.
See also section
(page
).
Selects the signal to be monitored by the peak value logger.
The signal is filtered using the filtering time specified by
parameter
.
The peak value is stored, along with other pre-selected
signals at the time, into parameters
…
.
The peak value logger can be reset using parameter
. The date and time of the last reset are stored
and
respectively.
Not selected
None (peak value logger disabled).
0
Motor speed used
.
1
Output frequency
3
Motor current
4
Motor torque
6
DC voltage
7
Output power
. 8
Speed ref ramp in
.
10
Speed ref ramp out
11
Speed ref used
.
12
Torque ref used
Not applicable
Freq ref used
14
Process PID out
.
16
).
-
Peak value logger filtering time. See parameter
2.00 s
0.00…120.00 s
Peak value logger filtering time.
100 = 1 s
Selects the signal to be monitored by amplitude logger 2. The
signal is sampled at 200 ms intervals.
The results are displayed by parameters
…
Each parameter represents an amplitude range, and shows
what portion of the samples fall within that range.
The signal value corresponding to 100% is defined by
parameter
.
Amplitude logger 2 can be reset using parameter
. The date and time of the last reset are stored into
and
respectively.
For the selections, see parameter
See parameter
for the selections.
Defines the monitored signal value for the amplitude logger
AL2 that corresponds to 100% sample value.
100.00
0.00…32767.00
Signal value corresponding to 100%.
1 = 1
Resets the peak value logger and/or amplitude logger 2.
(Amplitude logger 1 cannot be reset.)
Done
Reset completed or not requested (normal operation).
0
All
Reset both the peak value logger and amplitude logger 2.
1
PVL
Reset the peak value logger.
2
No.
Name/Value
Description
Def/FbEq16
ACQ80 FW.book Page 127 Thursday, February 14, 2019 11:33 AM
Содержание ACQ80-04 Series
Страница 4: ...4 ACQ80 FW book Page 4 Thursday February 14 2019 11 33 AM ...
Страница 10: ...10 Table of contents ACQ80 FW book Page 10 Thursday February 14 2019 11 33 AM ...
Страница 16: ...16 Introduction to the manual ACQ80 FW book Page 16 Thursday February 14 2019 11 33 AM ...
Страница 26: ...26 Start up control with I O and ID run ACQ80 FW book Page 26 Thursday February 14 2019 11 33 AM ...
Страница 28: ...28 Using the control panel ACQ80 FW book Page 28 Thursday February 14 2019 11 33 AM ...
Страница 54: ...54 Program features ACQ80 FW book Page 54 Thursday February 14 2019 11 33 AM ...
Страница 196: ...196 Additional parameter data ACQ80 FW book Page 196 Thursday February 14 2019 11 33 AM ...
Страница 220: ...220 Fault tracing ACQ80 FW book Page 220 Thursday February 14 2019 11 33 AM ...
Страница 260: ...260 Fieldbus control through a fieldbus adapter ACQ80 FW book Page 260 Thursday February 14 2019 11 33 AM ...
Страница 264: ...264 Parameterization with drive composer ACQ80 FW book Page 264 Thursday February 14 2019 11 33 AM ...
Страница 268: ...268 Parameterization with automation builder drive manager ACQ80 FW book Page 268 Thursday February 14 2019 11 33 AM ...