![ABB AC500-S Скачать руководство пользователя страница 369](http://html.mh-extra.com/html/abb/ac500-s/ac500-s_safety-user-manual_2916369.webp)
Table 75: FB Name: SF_EnableSwitch
Name
Data Type
Initial Value
Description, Parameter Values
VAR_INPUT
Activate
BOOL
FALSE
Table 31 “General Input Parameters”
S_SafetyActive
BOOL
FALSE
Variable or constant.
Confirmation of the safe mode (limitation of the
speed or the power of motion, limitation of the
range of motion).
FALSE: Safe mode is not active.
TRUE: Safe mode is active.
S_Enable-
SwitchCh1
BOOL
FALSE
Variable.
Signal of contacts E1 and E2 of the connected
enable switch.
FALSE: Connected switches are open.
TRUE: Connected switches are closed.
S_Enable-
SwitchCh2
BOOL
FALSE
Variable.
Signal of contacts E3 and E4 of the connected
enable switch.
FALSE: Connected switches are open.
TRUE: Connected switches are closed.
S_AutoReset
BOOL
FALSE
Table 31 “General Input Parameters”
Reset
BOOL
FALSE
Table 31 “General Input Parameters”
VAR_OUTPUT
Ready
BOOL
FALSE
Table 32 “General Output Parameters”
S_Enable-
SwitchOut
BOOL
FALSE
Safety related output: Indicates suspension of
guard.
FALSE: Disable suspension of safeguarding.
TRUE: Enable suspension of safeguarding.
Error
BOOL
FALSE
Table 32 “General Output Parameters”
DiagCode
WORD
16#0000
Table 32 “General Output Parameters”
Typical Timing Diagrams
Configuration and programming
AC500-S Libraries > SafetyBlocks_PLCopen_AC500_v22.lib
30.03.2017
AC500-S
369