Table 66: FB Name: SF_MutingSeq
Name
Data Type
Initial Value
Description, Parameter Values
VAR_INPUT
Activate
BOOL
FALSE
Table 31 “General Input Parameters”
S_AOPD_In
BOOL
FALSE
Variable.
OSSD signal from AOPD.
FALSE: Protection field interrupted.
TRUE: Protection field not interrupted.
MutingSwitch11
BOOL
FALSE
Variable.
Status of Muting sensor 11.
FALSE: Muting sensor 11 not actuated.
TRUE: Workpiece actuates muting sensor 11.
MutingSwitch12
BOOL
FALSE
Variable.
Status of Muting sensor 12.
FALSE: Muting sensor 12 not actuated.
TRUE: Workpiece actuates muting sensor 12.
MutingSwitch21
BOOL
FALSE
Variable.
Status of Muting sensor 21.
FALSE: Muting sensor 21 not actuated.
TRUE: Workpiece actuates muting sensor 21.
MutingSwitch22
BOOL
FALSE
Variable.
Status of Muting sensor 22.
FALSE: Muting sensor 22 not actuated.
TRUE: Workpiece actuates muting sensor 22.
S_MutingLamp
BOOL
FALSE
Variable or constant.
Indicates operation of the muting lamp.
FALSE: Muting lamp failure.
TRUE: Muting lamp no failure
MutingEnable
BOOL
FALSE
Variable or constant.
Command by the control system that enables the
start of the muting function when needed by the
machine cycle. After the start of the muting func-
tion, this signal can be switched off.
FALSE: Muting not enabled
TRUE: Start of Muting function enabled
S_StartReset
BOOL
FALSE
Table 31 “General Input Parameters”
Configuration and programming
AC500-S Libraries > SafetyBlocks_PLCopen_AC500_v22.lib
30.03.2017
AC500-S
336