13
RS-232 Protocol & Telnet Commands
RS-232 Protocol
SIGNAL GENERATOR
REMOTE CONTROL
PIN
ASSIGNMENT
PIN
ASSIGNMENT
1
NC
1
NC
2
TxD
2
RxD
3
RxD
3
TxD
4
NC
4
NC
5
GND
5
GND
6
NC
6
NC
7
NC
7
NC
8
NC
8
NC
9
NC
9
NC
RS-232 & Telnet Commands
Before using the commands, please read the following:
SYNTAX
• All commands
MUST
start with the
“$”
character or the command will not be recognized
by the unit. Commands must end with a carriage return (0x0D). Use of a line feed (0x0A)
is optional. Commands are not case-sensitive.
PARAMETERS
• The characters
“[“ and “]”
are placed around descriptions of the variable parameters
where additional explanation was needed. Please type the selected parameter without
the contents inside the
“[“ and “]”
characters when entering the command.
RESPONSES
• The unit will respond to most commands with a repeat of the original command followed
by the specified parameters or requested information except where otherwise noted. If
an invalid command is entered the unit will respond with
“$err”
.
• All unit responses end with a carriage return (0x0D) + line feed (0x0A).
CAUTIONS
• Only one command may be processed at a time. Additional commands should not be
sent until the response from the previous command has been received.
Baud Rate: 115200bps
Data Bits: 8
Parity: None
Flow Control: None
Stop Bit: 1