Error and Notification Messages
www.3ware.com
237
For more information on scheduling rebuilds, see “Scheduling Background
Tasks” on page 161
003C Initialize paused
This message will be sent when the initialization is paused.
Initializations are normally paused for ten minutes after a system first boots
up and during non-scheduled times when scheduling is enabled. Initializations
follow the rebuild schedule.
For information on the current task schedules, see “Viewing Current Task
Schedules” on page 162.
For information on initialization, see “About Initialization” on page 148
003D Verify paused
This message will be sent when the verify operation is paused.
Verifies are normally paused for ten minutes after a system first boots up and
during non-scheduled times when scheduling is enabled.
003E Migration paused
This message is sent when migration is paused. Migration follows the rebuild
schedule. For more information, see “Scheduling Background Tasks” on
page 161.
003F Flash file system error detected
The 3ware RAID controller stores some configuration parameters as files in
its flash memory. This message will be sent when a corrupted flash file system
is found on the controller during boot-up. A further attempt will be made to
repair the flash file system. These files usually get corrupted when a flash
operation is interrupted by events such as power failures.
0040 Flash file system repaired
This message will be sent if a corrupted flash file system is successfully
repaired. Some of the flash files with insufficient data may be lost in the
operation. The configuration parameters which are lost will then return to
their default values.
0041 Unit number assignments lost
The 3ware RAID controller tries to keep the unit numbers persistent across
soft resets. This message will be sent if unit number assignments were lost