Error and Notification Messages
www.3ware.com
227
Error and Notification Message Details
0001 Controller reset occurred
The 3ware RAID controller has detected a soft reset from the device driver. If
the 3ware RAID controller fails to respond to the device driver within a
reasonable amount of time, the device driver may issue a soft reset to the
3ware RAID controller and retry the command packet. For more information,
see
http://www.3ware.com/KB/article.aspx?id=14923.
0002 Degraded unit
An error has been encountered and the unit is operating in degraded (non-
redundant) mode. You should replace the bad drive as soon as possible and
initiate a rebuild.
Removing a drive from a redundant unit will cause this message to display
immediately.
For more information, see “Locating a Drive by Blinking Its LED” on
page 166.
0003 Controller error occurred
The 3ware RAID controller has encountered an internal error. Please contact
AMCC Customer Support as a replacement board may be required.
0004 Rebuild failed
The 3ware RAID controller was unable to complete a rebuild operation. This
error can be caused by drive errors on either the source or the destination of
0058 Battery capacity is below warning level
0059 Battery capacity is below error level
005A Battery is present
005B Battery is not present
005C Battery is weak
005D Battery health check failed
005E Cache synchronization completed
005F Cache synchronization failed; some data lost
Table 13: Error and Notification Message List