Chapter 9. Maintaining Units
158
3ware Serial ATA RAID Controller User Guide
Figure 67. Degraded Disk Array Warning Message
2
Press a key to continue.
3
If your degraded unit has a drive indicated as
Not in Use
, the drive may
still be usable. Try rebuilding with the
Not in Use
drive intact. Simply
select the unit (highlight it and press
Enter
) and then select the
Rebuild
Unit
button.
4
When the
Rebuild
confirmation screen appears, confirm that you selected
the correct unit by selecting
OK
.
5
Press
F8
to save your changes and exit 3BM
.
The unit will begin
rebuilding after the operating system finishes loading.
If the rebuild fails and you have no available drives, do one of the following:
•
If your system has hot-swap carriers, you can replace the failed or
Not In
Use
drive and rescan (Alt-R) the unit.
•
If your system does not have hot-swap carriers, power down the system
and replace the failed or
Not In Use
drive. Then power on the system and
restart 3BM.
Then follow these steps:
1
At the main 3BM screen, highlight an available drive to replace the
faulted drive and press
Enter
to select it.
An asterisk appears in the left most column to indicate the drive is
selected.
2
Press
Tab
to select the degraded unit and press
Enter
to select it.
3
Tab
to the
Maintain Unit
button and press
Enter
.
4
Select
Rebuild
from the pop-up menu and press
Enter
.