Set the rotary switch (under the front glass) to position 1 to make ALARM
/CANCEL be controlled by contact closing or voltage connection.
Contact opening/voltage disconnection control of ALARM, contact closing/voltage
connection control of CANCEL
Set the rotary switch (under the front glass) to position 2 to make ALARM be
controlled by contact opening or voltage disconnection and CANCEL be
controlled by contact closing or voltage connection.
Contact closing/voltage connection control of ALARM, contact opening/voltage
disconnection control of CANCEL
Set the rotary switch (under the front glass) to position 3 to make ALARM be
controlled by contact closing or voltage connection and CANCEL be controlled
by contact opening or voltage disconnection.
Contact opening/voltage disconnection control of ALARM and CANCEL
Set the rotary switch (under the front glass) to position 4 to make ALARM and
CANCEL be controlled by contact opening or voltage disconnection.
Caution
Use 6 to 24 V DC of any polarity. However, make sure that the power
supply is backed up against power outage.
Combine the control with buttons if you need to activate ALARM and
CANCEL from more sites.
CANCEL input connection (door contact, optional)
This input helps you cancel the rescue request if the lift is fully functional. Press
ALARM to make the system wait for a defined period of time, which slightly longer
than the maximum lift ride. If functional, the lift reaches the required station and opens
the door within the timeout, thus cancelling the rescue request. If the lift door does
n o t
o p e n ,
t h e
r e s c u e
r e q u e s t
i s
a c c e p t e d .
Make sure before installation that the door opening signal is available in the lift cabin.
Requirements
If the lift is equipped with a double door, the signal must be active only if both
the door parts are open and the people can leave the cabin safely.
The door opening signal must be active even during power outage.
Note
Make sure that delayed calling is configured to make the CANCEL input
Содержание Lift8
Страница 1: ...www 2n cz 2N Lift8 Communicator for lifts User Manual Firmware Version 2 3 1 ...
Страница 27: ...2N TELEKOMUNIKACE a s www 2n cz 27 377 2 1 PSTN GSM UMTS VoIP Central Unit Description Central Unit ...
Страница 28: ...2N TELEKOMUNIKACE a s www 2n cz 28 377 Indication Elements ...
Страница 40: ...2N TELEKOMUNIKACE a s www 2n cz 40 377 Examples of Connection ...
Страница 70: ...2N TELEKOMUNIKACE a s www 2n cz 70 377 ...
Страница 95: ...2N TELEKOMUNIKACE a s www 2n cz 95 377 ...
Страница 136: ...2N TELEKOMUNIKACE a s www 2n cz 136 377 User name Admin Password 2n ...
Страница 202: ...2N TELEKOMUNIKACE a s www 2n cz 202 377 Connection two cabin lift ...
Страница 210: ...2N TELEKOMUNIKACE a s www 2n cz 210 377 ...
Страница 356: ...2N TELEKOMUNIKACE a s www 2n cz 356 377 s ...
Страница 371: ...2N TELEKOMUNIKACE a s www 2n cz 371 377 13 1 Troubleshooting For the most frequently asked questions refer to faq 2n cz ...