Chapter 30 Error-Disable
XGS1930 Series User’s Guide
238
Figure 170
Advanced Application > Errdisable > Errdisable Status
The following table describes the labels in this screen.
Table 115 Advanced Application > Errdisable > Errdisable Status
LABEL
DESCRIPTION
Inactive-reason
mode reset
Port List
Enter the number of the ports (separated by a comma) on which you want to reset inactive-
reason status.
Cause
Select the cause of inactive-reason mode you want to reset here.
Reset
Press to reset the specified ports to handle ARP, BPDU or IGMP packets instead of ignoring them,
if the ports is in inactive-reason mode.
Errdisable Status
Port
This is the number of the port on which you want to configure Errdisable Status.
Cause
This displays the type of the control packet received on the port or the feature enabled on the
port and causing the Switch to take the specified action.
Active
This field displays whether the control packets (ARP, BPDU, and/or IGMP) on the port is being
detected or not. It also shows whether loop guard is enabled on the port.