XGS1930 Series User’s Guide
216
The following table describes the labels in this screen.
26.3.2 DHCP Snooping VLAN Configure
Use this screen to enable DHCP snooping on each VLAN and to specify whether or not the Switch adds
DHCP relay agent option 82 information to DHCP requests that the Switch relays to a DHCP server for
each VLAN.
To open this screen, click
Advanced Application
>
DHCP Snooping
>
Configure
>
VLAN
.
Figure 153
Advanced Application > DHCP Snooping > Configure > VLAN
Table 100 Advanced Application > DHCP Snooping > Configure > Port
LABEL
DESCRIPTION
Port
This field displays the port number. If you configure the
*
port, the settings are applied to all
of the ports.
*
Settings in this row apply to all ports.
Use this row only if you want to make some settings the same for all ports. Use this row first to
set the common settings and then make adjustments on a port-by-port basis.
Note: Changes in this row are copied to all the ports as soon as you make them.
Server Trusted state
Select whether this port is a trusted port (
Trusted
) or an untrusted port (
Untrusted
).
Trusted ports are connected to DHCP servers or other switches, and the Switch discards
DHCP packets from trusted ports only if the rate at which DHCP packets arrive is too high.
Untrusted ports are connected to subscribers, and the Switch discards DHCP packets from
untrusted ports in the following situations:
• The packet is a DHCP server packet (for example, OFFER, ACK, or NACK).
• The source MAC address and source IP address in the packet do not match any of the
current bindings.
• The packet is a RELEASE or DECLINE packet, and the source MAC address and source
port do not match any of the current bindings.
• The rate at which DHCP packets arrive is too high.
Rate (pps)
Specify the maximum number for DHCP packets (1 – 2048) that the Switch receives from
each port each second. The Switch discards any additional DHCP packets. Enter 0 to
disable this limit, which is recommended for trusted ports.
Apply
Click
Apply
to save your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the
Save
link on the top navigation panel to
save your changes to the non-volatile memory when you are done configuring.
Cancel
Click this to reset the values in this screen to their last-saved values.