![ZyXEL Communications NXC-8160 User Manual Download Page 82](http://html1.mh-extra.com/html/zyxel-communications/nxc-8160/nxc-8160_user-manual_943643082.webp)
Chapter 7 Advanced Settings
NXC-8160 User’s Guide
82
7.5 The Centralized Configuration Screen
Click
Advanced >
Centralized Configuration
to open this screen. Centralized Configuration
allows you to configure multiple NXC-8160 devices (a collection known colloquially as
slaves or member devices) through a single NXC-8160 device (known as the master
controller). The devices must be able to communicate with one another.
RADIUS Redundancy Selection
Changed <ESSID><#of
RADIUS>to<# of RADIUS>
This trap is sent when the RADIUS selection has been changed
from one server to another, and includes the ESSID, the
number of the previous server and the number of the new
server.
No RADIUS <ESSID>
This trap is sent when the last RADIUS server failed and
includes the ESSID.
Configured and connected
APs of channel [<channel
number>]
This trap provides a summary of all APs and their status. This
trap is typically sent after an event of AP removal or connection
from/to the switch.
AP <ap number in hex base>
has been connected
This trap is typically sent after an event of connecting an AP to
the switch.
AP <ap number in hex base>
has been disconnected
This trap is typically sent after an event of disconnecting an AP
from the switch.
Reference Host is up
This trap is sent when the reference server is up and active.
Sent by the main NXC-8160.
Reference Host is down
This trap is sent when the reference server is down. Sent by the
main NXC-8160.
Standby Switch is up
This trap is sent when the standby NXC-8160 is up and active.
Standby Switch is down
This trap is sent when the standby NXC-8160 is down.
Inactive - Reference Host
is down
This trap is sent when the reference server is down, and hence
the main NXC-8160 becomes inactive.
Inactive Standby Switch -
Main Switch is up
This trap is sent when the main NXC-8160 becomes active
again and hence the standby NXC-8160 becomes inactive
(switch over).
Main Switch is active again
This trap is sent when the main NXC-8160 changes status from
inactive to active and regains the main NXC-8160 status.
Failure detected in Main
Switch - Switching Over
This trap is sent when the main NXC-8160 is about to go down
and the standby NXC-8160 is becoming Active.
Table 32
SNMP Traps (continued)
TRAP TYPE
DESCRIPTION
Table 33
ZyXEL Centralized Configuration Specifications
Maximum number of centralized
configuration members
6
Centralized Configuration Member
Models
This device must be compatible with ZyXEL centralized
configuration implementation.
Master Controller
This is the device through which you manage the member
devices.
Member Controllers
These are the devices being managed by the master device.
Summary of Contents for NXC-8160
Page 1: ...www zyxel com NXC 8160 Business WLAN Controller User s Guide Version 1 0 12 2008 Edition 2...
Page 2: ......
Page 8: ...Safety Warnings NXC 8160 User s Guide 8...
Page 10: ...Contents Overview NXC 8160 User s Guide 10...
Page 21: ...21 PART I Introduction Getting to Know Your NXC 8160 23 Introducing the Web Configurator 27...
Page 22: ...22...
Page 32: ...Chapter 2 Introducing the Web Configurator NXC 8160 User s Guide 32...
Page 34: ...34...
Page 64: ...64...
Page 74: ...74...
Page 100: ...Chapter 8 Events Reports NXC 8160 User s Guide 100...
Page 101: ...101 PART V Troubleshooting and Specifications Troubleshooting 103 Product Specifications 107...
Page 102: ...102...
Page 110: ...Chapter 10 Product Specifications NXC 8160 User s Guide 110...
Page 112: ...112...
Page 136: ...Appendix A Setting Up Your Computer s IP Address NWD271N User s Guide 136...
Page 160: ...Appendix B Importing Certificates Document Title 160...
Page 178: ...Appendix D Pop up Windows JavaScripts and Java Permissions NXC 8160 User s Guide 178...
Page 196: ...Appendix F Legal Information NXC 8160 User s Guide 196...
Page 202: ...Appendix G Customer Support NXC 8160 User s Guide 202...