Appendix B
Table
of Cable Connections
B-3
Serial
No.
Cable Name
Connection of Terminal A
Connection of Terminal B
Remarks
12
DX06
MPD_X4
Power lightning arrester
13 ACDX03
MPD_HP
Heater
Power lightning arrester (blue,
brown)
14 ACDX01
POWER (at the bottom of the
cabinet)
Grounding point (black)
15
ACDX02
MPD_X1
Power lightning arrester
16 ACDX04
ACDX01_A
External
AC
power
The configuration in
case that AC power
is supplied
17 F-DC
PWR-001
POWER (at the bottom of the
cabinet)
Power lightning arrester
18
F-DC PWR-002
F-DC PWR-001_A
External -48V power
19 F-DC
PWR-003
(Blue) MPD_V-
(Black) MPD_V+
Power lightning arrester
The configuration in
case that DC power
is supplied
20 RF22
(Black)
MPD_V+
MDUP800_RX
21 RF24
MTRX800_RX1
MLNA800-2_RFOUT1
22 RF25
MTRX800_TX
MPA800_IN
23 RF27
RFE-ANT1 (at the bottom of the
cabinet)
MDUP800_ANT
24 RF28
MPA800_OUT
MDUP800_TX
25 RF29
GPS-ANT (at the bottom of the
cabinet)
MGPS_ANT
26 RF30
MGPS_10M
BDM800_X7
27
RF31
BDM800_X8
Middle hole of BRFS_X1
28 RF42
MLNA800-2_RFOUT2
RFE-ANT0 (at the bottom of the
cabinet)
29 RF43
MTRX800_RX0
EXTEND (at the bottom of the
cabinet)
30 GPS-BDM BDM800_X3
BGPS_X2
Note: Please refer to precautions listed in Table B
-
1.
B.3 Cable Connections in R800T Single-carrier Remote Stations
Table B.3-1 Cable Connections in R800T Single-carrier Remote Stations
Serial
No.
Cable Name
Connection of Terminal A
Connection of Terminal B
Remarks
1 DCDX01
BRFS_X5
MPD_X11
2 DCDX02
MPD_X6
MPA800
3 DCDX03
MPD_X7
MLNA800