ZSC-1000 User Manual.doc
Issue 18
Page 19 of 46
M
E
Y
E
R
T
E
C
H
L
I
M
I
T
E
D
Z
S
C
-1
0
0
0
Baud Rate
Defines the baud rate at which the ZVM port communications occurs.
Valid values are 1200, 2400, 4800, 9600, 19200, 38400.
Default = 9600
Camera Telemetry
Receiver setup
For each camera in the range 1 to 4096 (256 for a ZSC-500 or ZSC-1000) the following can be configured
Port
Which port the telemetry will be broadcast on.
The valid options are zvm, zvr1, zvr2, zvr3, zvr4 or pc1
Defaults
cameras 1-64 = zvr1
cameras 65-128 = zvr2
cameras 129-192 = zvr3
cameras 193-4096 = zvr4
Polled
If enabled the camera at this address will be polled (allows the receiver to return alarm and/or status
information)
Default = Off
Reversed
To correct for reversals in individual cameras. Where a direction(s) is reversed tick the appropriate
box(es) to translate all command to the camera. E.g. Tick
Pan
to transpose left & right commands.
Default = Off
Port setup
For each ZVR port (1,2,3 and 4) the following can be configured
Mode
The operation of the port either RS422 (2 or 4 wire) or RS485 (2 wire)
Default = RS485
Baud rate
Defines the baud rate at which the ZVR communications occurs.
Valid values are 1200, 2400, 4800, 9600, 19200, 28800, 38400,57600 and 128000.
Default = 9600
Protocol
The port can be configured to control a number of third party protocols. Those required must be
specified at time of order.
Default = ZoneVu