Sequence switch updates
If enabled then sequences running on the site controller will update the keyboards with current cross points.
This is disabled by default to prevent excessive data on the ZVK port and to match the functionality of
sequences running on a matrix
Default = Off
Enable Multiple ZVM Polls
If enabled then the site controller will reply to polls from the matrix more often, this feature has been added to
improve performance of telemetry when routed via the ZVM port. This is disabled by default as telemetry is
usually routed via the ZVR ports
Default = Off
Disable ZVM Local Switching
If enabled the site controller will ignore switch confirmations from the Matrix
Default = On
Disable Memory Check
If enabled the site controller will not attempt to automatically recover from memory faults
Default = Off
Prioritised trunk allocation
If enabled input trunks will be allocated based on the operator’s priority, instead of the default ‘first come first
served’ basis.
Default = Off
Barred camera input
If enabled the site controller will automatically display a fixed camera input when an operator selects a
camera that is barred to them. The input selected is the last on Matrix 0.
Default = Off
Legacy VCR / MUX protocol
Enable this option to gain control of some older Multiplexer / VCR interfaces
Default = Off
Disable auto dialup
Enable this option to prevent the controller automatically issuing ‘dialup’ & ‘hangup’ commands to ZSI
devices, when dialup trunks are used to view a remote site. Manual dialup is then required by the operator.
Default = Off
Switch over ZSC for Dual Redundancy
Enable this option if this ZSC will be the dual redundancy failsafe controller
Default = Off
Pelco extended address range
Enable this option if you do not require strict compatibility with the Pelco ‘P’ protocol, and wish to extend the
address range for Pelco ‘P’ telemetry receivers from 32 to 255.
Default = Off
No Proxy control over simplex sites
When requesting control of a camera range that maps to a simplex site, the default behaviour is to validate
the request against the local controllers camera range, or if video is mapped through a duplex site to pass the
request to it.
This Proxy behaviour can be disabled using this option, whereby the controller simply forwards the request to
the simplex site and assumes success.
Default = Off